English
Language : 

SL1002A Datasheet, PDF (2/2 Pages) Littelfuse – Greentube™ SL1002A Series Gas Plasma Arrester
High Performance Beta Range
RoHS Pb Greentube™ SL1002A Series Gas Plasma Arrester ®
LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
Part
Number*
SL1002A090
SL1002A230
SL1002A250
SL1002A260
SL1002A350
SL1002A600
DC Breakover
Voltage @100 V/s
Volts
MIN
70
184
200
210
280
480
MAX
120
276
300
310
420
720
MAX Dynamic
Breakover
Voltage1
100 V/µs
Volts
360
1kV/µs
Volts
700
400
500
400
500
400
500
500
600
800
900
AC
Discharge
Current2
Amps
5
5
5
5
5
5
*Max capacitance is 1.2 pF, measured at 1 MHz, zero volt bias
Notes:
1. Comparable to the silicon measurement Switching Voltage (Vs)
2. 10 shots, AC 60Hz, 1µs duration
3. 10 shots, 8/20µs waveform per IEC 61000-4-5
4. Measured at 100V, except 90VDC devices wich are measured at 50V
5. Tested according to ITU-T Rec. K.12
Max
Repetitive
Impulse
Current3
kAmps
5
5
5
5
5
5
MAX Single
Impulse Current
2/10 µs 2/350 µs
kAmps kAmps
2
2
2
2
2
2
2
2
2
2
2
2
Max
Leakage
Current4
nAmps
100
100
100
100
100
100
Holdover
Voltage5
Volts
50
135
135
135
135
135
Nominal
On-state
Voltage
@1A
Volts
20
20
20
20
20
20
8
Voltage vs Time Characteristic
Max dynamic breakover
voltage
Hold-over voltage
On-State voltage
0
200
400
600
800
1000 1200
Time (ns)
Typical Insertion Loss
@ 1.0 GHz = 0.01 dB
@1.4GHz = 0.1dB
@1.8 GHz = 0.53 dB
@2.1 GHz = 0.81 dB
@2.45 GHz= 1dB
@2.8 GHz = 1.2 dB
@3.1 GHz = 1.5dB
@3.5 GHz = 2.1 dB
www.littelfuse.com
326