English
Language : 

A0710SCLRP Datasheet, PDF (2/4 Pages) Littelfuse – Low on-state voltage
SIDACtor® Protection Thyristors
LCAS Protection
Surge Ratings
0.2x310 1
0.5x700 2
A min
C
50
2x10 1
2x10 2
A min
500
8x20 1
1.2x50 2
A min
400
10x160 1
10x160 2
A min
200
I
PP
10x560 1
10x560 2
A min
150
5x320 1
9x720 2
A min
200
10x360 1
10x360 2
A min
175
10x1000 1
10x1000 2
A min
100
5x310 1
10x700 2
A min
200
I
TSM
50/60 Hz
di/dt
A min Amps/μs max
30
500
Notes:
1 Current waveform in μs
2 Voltage waveform in μs
- Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product.
- IPP ratings applicable over temperature range of -40ºC to +85ºC
- The device must initially be in thermal equilibrium with -40°C < T < +150°C
J
Thermal Considerations
Package
DO-214AA
Symbol
T
J
TS
R0JA
Parameter
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance: Junction to Ambient
Value
-40 to +150
-65 to +150
90
Unit
°C
°C
°C/ W
V-I Characteristics
+I
IT
IS
IH
IDRM
-V
+V
VT
VDRM
VS
-I
Normalized VS Change vs. Junction Temperature
tr x td Pulse Waveform
tr = rise time to peak value
100
Peak td = decay time to half value
Value
Waveform = tr x td
50
Half Value
0
0 tr
td
t – Time (μs)
Normalized DC Holding Current vs. Case Temperature
14
12
10
8
6
4
25 °C
2
0
-4
-6
-8
-40 -20 0 20 40 60 80 100 120 140 160
Junction Temperature (TJ) – °C
© 2012 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com for current information.
2
Revised: December 17, 2012
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20
25°C
0 20 40 60 80 100 120 140 160
CaseTemperature (T ) - ºC
C
A0710SCLRP