2AG Slo-Blo® Fuse 229/230 Series
SURGE WITHSTAND SPECIFICATIONS INDICATING SLO-BLO® FUSE
Our standard 229 and 230 Series Slo-Blo® fuses meet the demanding
requirements of the Telecom industry. These Fuses combine
conventional overcurrent protection with the ability to withstand high cur-
rent, short duration pulses. These fuses comply with the short circuit
requirements of UL 1459 for telephone equipment. Insulating Sleeve
Option available. We have characterized these fuses for the Telecom
industry requirements as shown below.
ELECTRICAL CHARACTERISTICS:
Short Circuit Capabilities:
UL 60950 (UL 1459 Included): 60A, 600VAC
40A, 600VAC
7A,
600VAC
2.2A, 600VAC
• Meets UL 497 Specifications
PEAK WITHSTAND CURRENT (lp): These fuses will withstand 50
repetitions of a double exponential impulse wave having peak currents
(lp) and peak voltages as listed.
The 2AG Indicating Slo-Blo® fuse instantly identifies itself upon
opening by showing a discoloration of its glass body. Guesswork
and time consuming circuit testing are eliminated. This unique
design offers the same quality performance characteristics as
the standard 2AG fuse design.
Cartridge
Catalog
Number
229.250
229.350
229.375
229.500
229.600
229.750
229.800
229 001
229 1.25
Axial Lead
Catalog
Number
230.250
230.350
230.375
230.500
230.600
230.750
230.800
230 001
230 1.25
10 x 160
Ampere microsec.
Rating 1500V
1/4
23.0A
.350
34.0A
3/8
40.0A
1/2
60.0A
6/10
71.0A
3/4
91.0A
8/10
104.0A
1
130.0A
11/41
162.0A
1 500A peak, 2500V, 2 x 10 microseconds, 20 repetitions.
10 x 560
microsec.
800V
16.6A
25.8A
25.4A
37.7A
47.2A
65.5A
68.9A
88.6A
118.1A
10 x 1000
microsec.
1000V
12.4A
19.3A
19.0A
28.2A
35.3A
49.0A
51.6A
66.3A
100.0A
* When ordering the 2AG Indicating Slo-Blo Fuse, an ‘S’ is
required after the catalog number.
Example:
-1A Indicating Slo-Blo® Fuse = 230 001S
2AG 229 /230 Series General Specifications
2AG Special Surge Withstand
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature: –55°C to 125°C.
Shock: MIL-STD-202, Method 213, Test Condition I
(100 G’s peak for 6 milliseconds).
Vibration: MIL-STD-202, Method 201 (10–55 Hz, 0.06 inches
total excursion).
Salt Spray: MIL-STD-202 Method 101, Test Condition B (48 hours).
Insulation Resistance (After Opening): MIL-STD-202, Method 302,
Test Condition B.
Resistance to Soldering Heat: (Axial Leaded Fuses):
MIL-STD-202, Method 210A, Test Condition B (260°C, 3 Seconds).
Thermal Shock: MIL-STD-202, Method 107,
Test Condition B (–65°C to 125°C).
Moisture Resistance: MIL-STD-202, Method 106
(90-98% RH, 65°C).
Solderability: (Axial Leaded Fuses): MIL-STD-202,
Method 208.
PHYSICAL SPECIFICATIONS:
Materials: Glass Body, Nickel-Plated Brass Fuse Caps.
(Insulating sleeve option available).
Slo-Blo® Type
UL
®
AXIAL LEAD PART NUMBER: 220 003 (0.35A)
ELECTRICAL CHARACTERISTICS:
Amperes
0.35A
0.6A
2.0A
6.0A
Opening Time
4 hours, Minimum
90 seconds, Maximum
2 seconds, Maximum
0.5 second, Maximum
INTERRUPTING RATINGS: Same as 230 Series.
LIGHTNING SURGE WITHSTAND CAPABILITY: 25
amperes peak, 800V, 10 x 560 microseconds.
PATENTED
Refer to page 50 for other Surge Withstand Fuses.
SOLDERING PARAMETERS:
Wave solder — 500°F (260°C), 3 seconds Max.
Reflow solder — Not recommended.