English
Language : 

0469001.WR Datasheet, PDF (2/4 Pages) Littelfuse – Surface Mount Fuses
IntroductionSutorfaCcirecuMitouPnrottFeuctsieosn
Ceramic FuseTr>an4s6i9eSnteorlioegsy
Temperature Rerating Curve
140
120
100
80
60
40
-65 -45 -25 -5
15 35 55 75 95 115 135 155
TEMPERATURE (°C)
Average Time Current Curves
100
10
1
0.1
/PUF
1. Rerating depicted in this curve is in addition to the standard rerating of 20% for
continuous operation.
&YBNQMF
 'PSDPOUJOVPVTPQFSBUJPOBUEFHSFFTDFMTJVT UIFGVTFTIPVMECFSFSBUFEBTGPMMPXT
I = (0.80)(0.85)IRAT = (0.68)IRAT
0.01
0.001
1
10
100
CURRENT IN AMPERES
1000
Soldering Parameters
Reflow Condition
1CoGSFFBTTFNCMZ
- Temperature Min (Ts(min))
Pre Heat - Temperature Max (Ts(max))
- Time (Min to Max) (ts)
Average Ramp-up Rate (Liquidus Temp
(TL) to peak)
TS(max) to TL - Ramp-up Rate
Reflow
- Temperature (TL) (Liquidus)
- Temperature (tL)
Peak Temperature (TP)
Time within 5°C of actual peak
Temperature (tp)
Ramp-down Rate
Time 25°C to peak Temperature (TP)
Do not exceed
150°C
200°C
60 – 180 seconds
3°C/second max.
5°C/second max.
217°C
60 – 150 seconds
260+0/-5 °C
10 – 30 seconds
6°C/second max.
8 minutes max.
260°C
Wave Soldering
260°C, 10 seconds max.
TP
TL
TS(max)
Ramp-up
TS(min)
Preheat
tS
25
time to peak temperature
(t 25ºC to peak)
tP
Critical Zone
TL to TP
tL
Ramp-down
Time
469 Series
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/469.html for current information.