English
Language : 

VLD Datasheet, PDF (1/2 Pages) Littelfuse – POLYFUSE RESETTABLE FUSES
POLYFUSE® RESETTABLE FUSES
VLD
A
D1
D2
BE
Strap Type, 12 V
Standard
UL 1434 1st Edition
CSA C22.2 No. 0 CSA TIL No. CA-3A
Approvals
cULus Recognition
TÜV
Features
The new VLD product series feature a slim, low
profile and low resistance design. These devices
are ideal to install directly onto the latest genera-
tion batteries including cylindrical and prismatic
cells. The VLD product offers protection against
both overcurrent and overtemperature fault
conditions.
Specifications
Packaging
A small pack
D standard
Materials
Insulating material: Polyester Tape
Terminals:
Nickel
Operating / Storage Temperature
-40 ºC to +85 ºC (consider de-rating)
Humidity Ageing
+60 °C, 95 % R.H., 1000 hours, ± 10 % typical
resistance change
Vibration
MIL-STD-883C, Condition A, no change
Thermal Shock
MIL-STD-202F, Method 107G
+85 °C to -40 °C 10 times ±5 % typical
resistance change
Marking
A
“P”, Part Code, identification, lot number
D1
C
D2
C
BE
Figure 1
Dimensions (mm)
Model
Fig
A
Min Max
VLD170
1
VLD175L 2
VLD175XL 2
VLD230
1
20.8 23.2
29.3 31.7
25.5 28.2
20.9 23.1
B
Min Max
3.5 3.9
2.9 3.3
3.5 3.9
4.9 5.3
Figure 2
C
D1
D2
E
packaging quantity
Min Max Min Max Min Max
small pack
standard
0.8
4.5 6.5
4.5 6.5
2.4 2.6
500
0.8
5.2 6.8
10.0 12.5
2.4 2.6
500
0.8
8.7 10.3
5.7 7.3
2.4 2.6
500
0.8
4.1 5.8
4.1 5.8
3.9 4.1
500
10,000
10,000
10,000
10,000
Permissible continuous operating current is ≤ 100 % at ambient temperature of 25 ºC (77 ºF).
Model
Ihold
ITrip
Vmax. dc
Imax.
max. time to trip
(A)
(A)
(V)
(A)
(s @ A)
Pd max
(W)
Resistance
Approvals
R ( min. ) RI ( max. ) RI ( max. )
VLD170
1.70
4.10
VLD175L
1.75
4.20
VLD175XL
1.75
4.20
VLD230
2.30
5.00
12
100
5.0 @ 8.50
12
100
5.0 @ 8.75
12
100
5.0 @ 8.75
12
100
5.0 @ 10.0
1.40
0.018
0.032 0.064
••
1.40
0.017
0.031 0.062
••
1.40
0.017
0.031 0.062
••
2.50
0.012
0.018 0.036
••
NOTE:
I hold =
I trip =
Vmax =
I max =
Hold current: maximum current device will pass without tripping in 25 °C still air.
Trip current: minimum current at which the device will trip in 25 °C still air.
Maximum voltage device can withstand without damage at rated current (I max)
Maximum fault current device can withstand without damage at rated voltage (Vmax)
Pd = Power dissipated from device when in the tripped state at 25 °C still air.
R min= Minimum resistance of device in initial (un-soldered) state.
R = 1max Maximum resistance of device at 25 °C measured one hour after tripping for 20 s.
Caution:Operation beyond the specified rating may result in damage and possible arcing and flame.
Specifications are subject to change without notice
Order
Information
Qty.
Order-
Model Packaging
Number
041006
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com