SP6001-0XUTG-1 Datasheet, PDF (1/1 Pages) Littelfuse – LCD and camera interfaces in mobile devices are vulnerable to EMI from the cellular band | |||
|
Silicon Protection Arrays
Application Guide
LCD and Camera Interfaces (Mobile)
Considerations:
â LCD and camera interfaces in mobile devices are vulnerable to EMI from the cellular band
â Frequencies between 800-3000MHz should be attenuated to prevent distortion on the display
â The pixel clocks vary depending upon the display size but the frequency will typically fall between 5-65MHz
â This corresponds to data rates between 10-60Mbps and with these speeds line capacitances need to be
considered
â In the majority of applications line capacitances of 20-40pF will not cause signal integrity issues
â The protection schemes below for data lines Dx are only examples and will vary with the particular application
Application Schematic:
PCB Connector
for LCD Display
D1
D2
D3
D4
Camera Module
D1
D2
D3
D4
D5
D6
D7
D8
*Packages are shown as transparent
SP6001-04
Case GND
SP6001-08
Baseband
IC
Baseband
IC
Case GND
Recommended SPA Devices:
Ordering Number
SP6001-0xUTG-1
SP6002-0xUTG-1
ESD Level
(Contact)
±30kV
±30kV
Cut-off
Frequency
115MHz
100MHz
Line
Capacitance
24pF
30pF
# of
Channels
4/6/8
4/6
VRWM
6V
6V
Packaging
μDFN-8/12/16
μDFN-8/12
©2009 Littelfuse, Inc
20
|