English
Language : 

Q4004D3RP Datasheet, PDF (1/10 Pages) Littelfuse – Lxx04xx Qxx04xx Series
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Lxx04xx & Qxx04xx Series
®
Description
4 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in Quadrants
I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Agency Approval
Agency
®
Agency File Number
-1BDLBHF&
Main Features
Symbol
IT(RMS)
V /V
DRM RRM
IGT (Q1)
Value
4
400 to 1000
3 to 25
Schematic Symbol
Unit
A
V
mA
MT2
MT1
G
Features & Benefits
t3P)4$PNQMJBOU
t(MBTToQBTTJWBUFE
junctions
t7PMUBHFDBQBCJMJUZVQUP
1000 V
t4VSHFDBQBCJMJUZVQUP
55 A
t&MFDUSJDBMMZJTPMBUFE
“L-Package” is UL
recognized for 2500Vrms
t4PMJETUBUFTXJUDIJOH
eliminates arcing or
contact bounce that
create voltage transients
t/PDPOUBDUTUPXFBSPVU
from reaction of switching
events
t3FTUSJDUFE PSMJNJUFE 3'*
generation, depending on
activation point of
sine wave
t3FRVJSFTPOMZBTNBMMHBUF
activation pulse in each
half-cycle
Applications
Typical applications are AC solid-state switches, power
tools, home/brown goods and white goods appliances.
Sensitive gate Triacs can be directly driven by
microprocessor or popular opto-couplers/isolators.
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
Absolute Maximum Ratings — Sensitive Triacs (4 Quadrants)
Symbol
Parameter
IT(RMS)
RMS on-state current
(full sine wave)
ITSM
Non repetitive surge peak on-state current
(full cycle, T initial = 25°C)
J
I2t
I2t Value for fusing
di/dt
IGTM
P
G(AV)
Tstg
TJ
Critical rate of rise of on-state current
(I
G
=
50mA
with
c
0.1μs
rise
time)
Peak gate trigger current
Average gate power dissipation
Storage temperature range
Operating junction temperature range
Note: xx = voltage, y = sensitivity
Lxx04Ly / Lxx04Dy
Lxx04Ry / Lxx04Vy
f = 50 Hz
TC = 85°C
TC = 75°C
t = 20 ms
f = 60 Hz
t = 16.7 ms
tp = 8.3 ms
f = 120 Hz
TJ = 110°C
t
p
c
10
μs
T = 110°C
J
TJ = 110°C
©2010 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
51
Revised: July 29, 2010 09:54 AM
Value
4
33
40
6.6
50
1.2
0.3
-40 to 150
-40 to 110
Unit
A
A
A2s
A/μs
A
W
°C
°C
Lxx04xx & Qxx04xx Series