PGR-6100 Datasheet, PDF (1/1 Pages) Littelfuse – The PGR-6100 combines the features
Protection Relays & Controls
Motor Protection–Basic (PGR 6000 Family)
PGR-6100 SERIES (GFR4000)
Ground-Fault & Insulation Monitor
Simplified Circuit Diagram
CT A
A
GROUNDED B
SUPPLY
C
D
PGR-6100 SERIES
(Ground-Fault
L1
& Insulation Monitor)
L2
Ordering Information
ORDERING NUMBER
PGR-6100-120
PGR-6100-240(1)
CONTROL POWER
120 Vac
240 Vac (1)
ACCESSORIES
REQUIREMENT
PGC-5000 Series
Required
PGH Family
Required >1300 V
PGA-0500
Optional
PGA-0510
Optional
Note (1) - PGR-6100-240 ordering option is not UL Listed.
For optional conformal coating please consult factory.
© 2014 Littelfuse Protection Relays & Controls
Littelfuse.com/pgr-6100
Description
The PGR-6100 combines the features of a ground-fault
protection relay and insulation monitor into one unit.
It protects against ground faults by monitoring insulation
resistance when the motor is de-energized and by
monitoring ground-fault current when the motor is energized.
The PGR-6100 features two separate analog outputs for
optional current and ohm meters, and two separate alarm
relays. It operates on one- or three-phase solidly grounded,
resistance grounded and ungrounded systems up to 6 kV.
Features & Benefits
FEATURES
Adjustable GF pickup
(10 mA - 3 A)
Adjustable insulation
pickup (250 kΩ - 2 MΩ)
Adjustable time delay
(50 ms - 1.0 s)
Output contacts
Analog outputs
(0 - 1 mA)
BENEFITS
Trip setting provides a wide range of low-level
protection and system coordination
Customizable insulation resistance setpoints
for maximum protection
Adjustable trip delay for quick protection and
system coordination
Two Form C output contacts for ground fault and
insulation-resistance fault
Two analog outputs indicate insulation
resistance and ground-fault current
CT-Loop monitoring
Selectable contact
operating mode
Alarms when CT is not connected
Selectable fail-safe or non-fail-safe operating
modes allows connection to shunt or
undervoltage breaker coil
Accessories
A
PGC-5000 Series Ground-Fault Transformers
Required zero-sequence current transformer
specifically designed for low level detection. Flux
conditioner is included to prevent saturation.
B
PGA-0500 Analog % Current Meter
PGA-0510 Analog Ohm Meter
C
Optional panel-mounted meters display
ground-fault current as a percentage of the
set-point and insulation resistance.
D
PGH Family High Tension Couplers
Required (for systems >1,300 V) PGH Family
high-tension coupler must be connected between
the phase conductor and the PGR-6100.
Specifications
IEEE Device Numbers
Input Voltage
Dimensions
Response delay
Contact Operating Mode
Harmonic Filtering
Test Button
Reset Button
CT-Loop Monitoring
Output Contacts
Analog Output
Approvals
Warranty
Mounting
Ground Fault (50G/N, 51G/N),
Ground detector (64), Alarm Relay (74)
See ordering information
H 75 mm (3”); W 100 mm (3.9”); D 115 mm (4.5”)
< 250 ms
Selectable fail-safe or non-fail-safe
Standard feature
Standard feature
Standard feature
Standard feature
Two Form C
0-1 mA
UL Listed (E183688) (1)
5 years
DIN, Surface
Rev: 4-C-030614
Based on Manual Rev 2-A-013014