English
Language : 

P2000AA61L Datasheet, PDF (1/2 Pages) Littelfuse – SIDACtor
SIDACtor® Device
RoHS
This modified TO-220 package with Type 61 lead spacing offers a through-hole technology
SIDACtor protection solution.
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P2000AA61L
P2200AA61L
P2400AA61L
P2500AA61L
P3000AA61L
P3300AA61L
VDRM
Volts
180
200
220
240
270
300
VS
Volts
220
240
260
290
330
360
VT
Volts
4
4
4
4
4
4
IDRM
µAmps
5
5
5
5
5
5
IS
mAmps
800
800
800
800
800
800
IT
Amps
2.2
2.2
2.2
2.2
2.2
2.2
IH
mAmps
150
150
150
150
150
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
IPP
0.2x310 * 2x10 * 8x20 * 10x160 * 10x560 * 5x320 * 10x360 * 10x1000 * 5x310 * ITSM
0.5x700 ** 2x10 ** 1.2x50 ** 10x160 ** 10x560 ** 9x720 ** 10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz di/dt
Amps Amps Amps
Amps
Amps Amps Amps
Amps
Amps Amps Amps/µs
A
20
150
150
90
50
75
75
45
75
20
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 43