P1500NEL Datasheet, PDF (1/2 Pages) Littelfuse – CATV Line Amplifiers/Power Inserters 3 kA SIDACtor® Device
CATV Line Amplifiers/Power Inserters 3 kA SIDACtor® Device
RoHS
This SIDACtor device is a 3000 A solid state protection device offered in a non-isolated
1
2 TO-263 (D2) package. It protects equipment located in the severe surge environment of
CATV (Community Antenna TV) systems and antenna locations.
Electrical Parameters
Part
Number *
P1500NEL
P1900NEL
P2300NEL
VDRM
Volts
140
140
180
VS
Volts
180
220
260
VT
Volts
4
4
4
IDRM
µAmps
5
5
5
IS
mAmps
800
800
800
IT
Amps **
2.2/25
2.2/25
2.2/25
IH
mAmps
50
50
50
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
** IT is a free air rating; heat sink IT rating is 25 A.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
Series
E
IPP
8x20 *
1.2x50 **
Amps
3000
ITSM
50 / 60 Hz
Amps
400
di/dt
Amps/µs
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse