P0641SCRP Datasheet, PDF (1/2 Pages) Littelfuse – Fixed Voltage SLIC Protector
Fixed Voltage SLIC Protector
Fixed Voltage SLIC Protector
(T/R)
These DO-214AA unidirectional protectors are constructed with a SIDACtor device and an
integrated diode. They protect SLICs (Subscriber Line Interface Circuits) from damage
during transient voltage activity and enable line cards to meet various regulatory
requirements including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and
(G)
TIA-968-A (formerly known as FCC Part 68).
For specific design criteria, see details in Figure 3.22.
Cathode
Electrical Parameters
Part
Number *
P0641S_
P0721S_
P0901S_
P1101S_
P1701S_
VDRM
Volts
58
65
75
95
160
VS
Volts
77
88
98
130
200
VT
Volts
4
4
4
4
4
VF
IDRM
IS
IT
IH
CO
Volts
µAmps mAmps Amps
mAmps
pF
5
5
800
1
120
70
5
5
800
1
120
70
5
5
800
1
120
70
5
5
800
1
120
70
5
5
800
1
120
70
* For individual “SA” and “SC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• VDRM is measured at IDRM.
• VS and VF are measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value for “SA” and “SB” product. “SC” capacitance
is approximately 2x the listed value.
• Parallel capacitive loads may affect electrical parameters.
Surge Ratings (Preliminary Data)
Series
A
C
IPP
2x10 µs
Amps
150
500
IPP
8x20 µs
Amps
150
400
IPP
10x160 µs
Amps
90
200
IPP
10x560 µs
Amps
50
150
IPP
10x1000 µs
Amps
45
100
ITSM
60 Hz
Amps
20
50
di/dt
Amps/µs
500
500
http://www.littelfuse.com
+1 972-580-7777
2 - 42
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide