MicroCapacitance (MC) SIDACtor Device
MicroCapacitance (MC) SIDACtor Device
The TO-92 MC SIDACtor series is intended for applications sensitive to load values.
Typically, high speed connections require a lower capacitance. CO values for MC devices
are 40% lower than a standard EC part.
This MC SIDACtor series is used to enable equipment to meet various regulatory
requirements including GR 1089, ITU K.20, K.21, and K.45, IEC 60950, UL 60950, and
TIA-968-A (formerly known as FCC Part 68) without the need of series resistors.
Electrical Parameters
Part
VDRM
VS
VT
IDRM
IS
IT
IH
CO
Number *
Volts
Volts
Volts
µAmps
mAmps
Amps
mAmps
pF
P0640EC MC
58
77
4
5
800
2.2
150
60
P1500EC MC
140
180
4
5
800
2.2
150
50
P2600EC MC
220
300
4
5
800
2.2
150
40
P3100EC MC
275
350
4
5
800
2.2
150
40
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
Surge Ratings
Series
C
IPP
2x10 µs
Amps
500
IPP
8x20 µs
Amps
400
IPP
10x160 µs
Amps
200
IPP
10x560 µs
Amps
150
IPP
10x1000 µs
Amps
100
ITSM
60 Hz
Amps
50
di/dt
Amps/µs
500
http://www.littelfuse.com
+1 972-580-7777
2 - 18
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide