English
Language : 

P0302AAMCL Datasheet, PDF (1/3 Pages) Littelfuse – Two-chip MicroCapacitance
Two-chip MicroCapacitance (MC) SIDACtor® Device
RoHS
¨
This two-chip MicroCapacitance SIDACtor design provides a through-hole technology
1
(T)
2 protection solution. It is intended for telecom applications that do not require a balanced
3
(G) solution. For primary protection applications, devices with higher holding current and
(R)
integrated failsafe options are available.
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P0302AAMCL
P0602AAMCL
VDRM
Volts
VS
Volts
Pins 1-2, 3-2
6
25
25
40
VDRM
Volts
VS
Volts
Pins 1-3
12
50
50
80
VT
Volts
4
4
IDRM
µAmps
5
5
IS
mAmps
800
800
IT
Amps
2.2
2.2
IH
mAmps
50
50
Part
Number *
VDRM
Volts
VS
Volts
Pins 1-2, 3-2
VDRM
Volts
VS
Volts
Pins 1-3
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
P0602ACMCL
25
40
50
80
4
5
800
2.2
50
P1402ACMCL
58
77
116
154
4
5
800
2.2
150
P1602ACMCL
65
95
130
190
4
5
800
2.2
150
P2202ACMCL
90
130
180
260
4
5
800
2.2
150
P2702ACMCL
120
160
240
320
4
5
800
2.2
150
P3002ACMCL
140
180
280
360
4
5
800
2.2
150
P3602ACMCL
170
220
340
440
4
5
800
2.2
150
P4202ACMCL
190
250
380
500
4
5
800
2.2
150
P4802ACMCL
220
300
440
600
4
5
800
2.2
150
P6002ACMCL
275
350
550
700
4
5
800
2.2
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
0.2x310 * 2x10 * 8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
Amps Amps Amps
A
20
150
150
C
50
500
400
* Current waveform in µs
** Voltage waveform in µs
10x160 *
10x160 **
Amps
90
200
IPP
10x560 *
10x560 **
Amps
50
150
5x320 *
9x720 **
Amps
75
200
10x360 * 10x1000 * 5x310 *
ITSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz di/dt
Amps
Amps
Amps Amps Amps/µs
75
45
75
20
500
175
100
200
50
500
www.littelfuse.com
3 - 48