English
Language : 

P0084UCMCL Datasheet, PDF (1/3 Pages) Littelfuse – Multiport MicroCapacitance
Multiport MicroCapacitance (MC) SIDACtor® Device
RoHS
The multiport MC line protector is an integrated, multichip solution used for protecting
1
6 multiple twisted pair from overvoltage conditions. It is intended for applications
(R1)
(T2) sensitive to load values. Typically, high speed connections require lower capacitance.
2
5 CO values for the MC devices are 40% lower than standard UC devices.
(G1)
(G2) This six-pin surface mount SOIC is equivalent to four discrete DO-214AA, which
makes it ideal for densely populated, high-speed line cards that cannot tolerate PCB
3
(T1)
4
(R2)
inefficiencies nor the use of series power resistors. Surge current ratings up to 500 A
are available.
SIDACtor devices enable equipment to comply with various regulatory requirements including GR 1089, ITU
K.20, K.21, and K.45, IEC 60950, UL 60950, and TIA-968-A (formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P0084UCMCL
P0304UCMCL
P0644UCMCL
P0724UCMCL
P0904UCMCL
P1104UCMCL
P1304UCMCL
P1504UCMCL
P1804UCMCL
P2304UCMCL
P2604UCMCL
P3104UCMCL
P3504UCMCL
VDRM
Volts
VS
Volts
Pins 1-2, 3-2, 4-5, 6-5
6
25
25
40
58
77
65
88
75
98
90
130
120
160
140
180
170
220
190
260
220
300
275
350
320
400
VDRM
Volts
VS
Volts
Pins 1-3, 4-6
12
50
50
80
116
154
130
176
150
196
180
260
240
320
280
360
340
440
380
520
440
600
550
700
640
800
VT
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
IDRM
µAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
IS
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
IT
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
IH
mAmps
50
50
150
150
150
150
150
150
150
150
150
150
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
0.2x310 * 2x10 * 8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
10x160 *
10x160 **
IPP
10x560 *
10x560 **
5x320 *
9x720 **
10x360 * 10x1000 * 5x310 * ITSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
di/dt
Amps Amps Amps
Amps
Amps Amps Amps
Amps
Amps Amps Amps/µs
C
50
500
400
200
150
200
175
100
200
50
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 37
www.littelfuse.com