English
Language : 

P0080SD Datasheet, PDF (1/2 Pages) Littelfuse – High Surge Current (D-rated) SIDACtor Device
High Surge Current (D-rated) SIDACtor Device
High Surge Current (D-rated) SIDACtor Device
DO-214AA SIDACtor solid state protection devices with a D surge rating protect
telecommunications equipment such as modems, line cards, fax machines, and other CPE.
These SIDACtor devices withstand simultaneous surges incurred in GR 1089 lightning
tests. (See "First Level Lightning Surge Test" on page 4-5.) Surge ratings are twice that of a
device with a C surge rating. This allows a discrete surface mount version of Littelfuse’s
patented “Y” configuration. (US Patent 4,905,119)
SIDACtor devices are used to enable equipment to meet various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P0080SD **
P0300SD **
P0640SD **
P0720SD **
P0900SD **
P1100SD
P1300SD
P1500SD
P1800SD
P2300SD
P2600SD
P3100SD
P3500SD
VDRM
Volts
6
25
58
65
75
90
120
140
170
190
220
275
320
VS
Volts
25
40
77
88
98
130
160
180
220
260
300
350
400
VT
IDRM
IS
IT
IH
CO
Volts
µAmps
mAmps
Amps ***
mAmps
pF
4
5
800
2.2
50
200
4
5
800
2.2
50
220
4
5
800
2.2
50
100
4
5
800
2.2
50
100
4
5
800
2.2
50
100
4
5
800
2.2
50
80
4
5
800
2.2
50
80
4
5
800
2.2
50
80
4
5
800
2.2
50
60
4
5
800
2.2
50
60
4
5
800
2.2
50
60
4
5
800
2.2
50
60
4
5
800
2.2
50
60
* For surge ratings, see table below.
** Contact factory for release date.
*** The 2.2 A version cannot be used to meet 4.4 A requirements.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value.
Surge Ratings
Series
D
IPP
2x10 µs
Amps
1000
IPP
8x20 µs
Amps
800
IPP
10x160 µs
Amps
400
IPP
10x560 µs
Amps
300
IPP
10x1000 µs
Amps
200
ITSM
60 Hz
Amps
50
di/dt
Amps/µs
1000
http://www.littelfuse.com
+1 972-580-7777
2 - 10
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide