English
Language : 

P0080ECMCL Datasheet, PDF (1/3 Pages) Littelfuse – MicroCapacitance SIDACtor Device
0LFUR&DSDFLWDQFH 0& 6,'$&WRUŠ 'HYLFH
RoHS
¨
These TO-92 MC SIDACtor devices are intended for applications sensitive to load values.
Typically, high speed connections, such as xDSL and T1/E1, require a lower capacitance.
CO values for the MicroCapacitance device are 40 percent lower than a standard EC part.
This MC SIDACtor series enables equipment to comply with various regulatory
requirements including GR 1089, ITU K.20, K.21, and K.45, IEC 60950, UL 60950, and
TIA-968-A (formerly known as FCC Part 68) without the need of series resistors.
Electrical Parameters
Part
Number *
P0080ECMCL
P0300ECMCL
P0640ECMCL
P0720ECMCL
P0900ECMCL
P1100ECMCL
P1300ECMCL
P1500ECMCL
P1800ECMCL
P2300ECMCL
P2600ECMCL
P3100ECMCL
P3500ECMCL
VDRM
Volts
6
25
58
65
75
90
120
140
170
190
220
275
320
VS
Volts
25
40
77
88
98
130
160
180
220
260
300
350
400
VT
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
IDRM
μAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
IS
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
IT
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
IH
mAmps
50
50
150
150
150
150
150
150
150
150
150
150
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -+40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/μs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
IPP
0.2x310 * 2x10 * 8x20 * 10x160 * 10x560 * 5x320 * 10x360 * 10x1000 * 5x310 *
ITSM
0.5x700 ** 2x10 ** 1.2x50 ** 10x160 ** 10x560 ** 9x720 ** 10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
di/dt
Amps Amps Amps
Amps
Amps Amps Amps
Amps
Amps Amps Amps/μs
C
50
500
400
200
150
200
175
100
200
30
500
* Current waveform in μs
** Voltage waveform in μs
www.littelfuse.com
3 - 22
© 2006 Littelfuse, Inc. • Telecom Design Guide