English
Language : 

MRPR-8 Datasheet, PDF (1/2 Pages) HAMLIN Position and Movement Sensor Solutions – Miniature normally open switch size with 20.32mm x 2.84mm
Axial Lead Reed Switches
Low Power > MRPR-8
MRPR-8 20.3mm Miniature High Voltage Reed Switch
RoHS
Description
The MRPR-8 Reed Switch is a miniature, normally open switch with a 20.32mm
long x 2.84mm diameter (0.800” x 0.112”) glass envelope, capable of high
voltage and power switching of 265Vac at 50VA. The MRPR-8 has high
insulation resistance of 1010 ohms minimum and contact resistance less than
100 milli-ohms.
Features
• Miniature normally open switch
• Capable of switching 265Vac or
1.0A at up to 50W/VA
• Minimum voltage breakdown
750Vdc
• Available sensitivity range
22-43 AT
Agency Approvals
Agency
Agency File Number Ampere-Turns Range
E47258
E471070
DEMKO 14 ATEX 1393U
22-43 AT
22-43 AT
Dimensions
Dimensions in mm (inch)
CL OF OVERLAP
0.63
(.025) DIA. REF.
28.32
(1.115) REF.
2.84
(.112) MAX.
18.16
(.715) MAX.
20.32
(.800) MAX.
56.64
(2.230) NOM.
Benefits
• Hermetically sealed switch
contacts are not affected by and
have no effect on their external
environment
• Zero operating power required
for contact
Applications
• Reed relays (suitable for switching
European mains voltage)
• Limit switching
• Telecoms line switching
• White goods applications
• European mains voltage switching
Switch Type
Contact Form
A (SPST-NO)
Materials
Body: Glass
Leads: Tin-plated Ni-Fe wire
Note: SPST-NO = Single-pole, single-throw, normally open
Electrical Ratings
Contact Rating 1
Voltage 3
Current 3
Resistance
Capacitance
Temperature
Switching 2
Breakdown 4
Switching 2
Carry
Contact, Initial
Insulation
Contact
Operating
Storage 5
W/VA - max.
Vdc - max.
Vac - max.
Vdc - min.
Adc - max.
Aac - max.
Adc - max.
Ω - max.
Ω - min.
pF - typ.
°C
°C
50
250
265
750
1.0
0.7
2.5
0.100
1010
0.2
-20 to +125
-65 to +125
Notes:
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.
4. Breakdown Voltage - per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the leads.
© 2015 Littelfuse
Specifications are subject to change without notice.