English
Language : 

DRR-DTH Datasheet, PDF (1/2 Pages) Littelfuse – Axial Lead Reed Switches
Axial Lead Reed Switches
High Power > DRR-DTH
DRR-DTH 39.7mm Standard Changeover Reed Switch
RoHS
Description
The DRR-DTH Reed Switch is a large changeover switch with a 39.67mm long x
5.33mm diameter (1.562” x 0.210”) glass envelope, capable high voltage and
power switching up to 500Vdc at 30W. The DRR-DTH has an insulation
resistance of 109 ohms minimum and contact resistance of less than
125 milli-ohms.
The DRT-DTH Reed Swith, another varient of the DRR-DTH, is made for
heavier loads.
Dimensions
Dimensions in mm (inch)
1.83
(.072) NOM.
0.25
(.010) NOM.
1.27
(.050) DIA. REF.
5.54 CL OF OVERLAP
(.218) MAX.
27.66
(1.89) REF.
5.33
(.210) MAX.
25.40
(1.000) NOM.
12.45
(.490) NOM.
38.10 - 39.67
(1.500) NOM. - (1.562) MAX.
85.73 - 84.14
(3.375) NOM. - (3.3125) MIN.
1.02
(.040) DIA. REF.
Features
• Changeover switch
• Capable of switching 500Vdc or
0.5A at up to 30W
• Minimum voltage breakdown
1200Vdc
Benefits
• Hermetically sealed switch
contacts are not affected by and
have no effect on their external
environment
• Can be used as changeover or
normally closed contact
Applications
• Security
• Limit switching
• Available sensitivity range
50-80 AT
• Minimum voltage breakdown
1200Vdc
• Capable of switching European
mains voltage
• Zero operating power required for
contact closure
• Industrial safety applications
• White goods applications
Switch Type
Electrical Ratings
Contact Form
Materials
C (SPDT-CO)
Body: Glass
Leads: Tin-plated Ni-Fe wire
Note: SPDT-CO = Single-Pole, Double-Throw, Change Over
Contact Rating 1
W/VA - max.
30
Voltage 3
Current 3
Switching 2
Breakdown 4
Switching 2
Carry
Vdc - max.
Vac - max.
Vdc - min.
Adc - max.
Aac - max.
Adc - max.
500
350
1200
0.50
0.35
3.0
Resistance
Contact, Initial
Insulation
Ω - max.
Ω - min.
0.125
109
Capacitance
Contact
pF - typ.
2.0
Temperature
Operating
Storage 5
°C
-20 to +125
°C
-65 to +125
Notes:
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.
4. Breakdown Voltage - per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the leads.
© 2015 Littelfuse
Revised: 11/02/15
Specifications are subject to change without notice.
littelfuse.com