This solid state protection device can be referenced to either a positive or negative voltage
source. The B1xx0C_ is for a -VREF and the B2050C_ is for a +VREF. Designed using an
SCR and a gate diode, the B1xx0C_ Battrax begins to conduct at |-VREF| + |-1.2 V| while the
B2050C_ Battrax begins to conduct at |+VREF| + |1.2 V|.
For a diagram of a Battrax application, see Figure 3.38.
Pin 2
(Ground)
Pin 3
(-VREF)
Gate
-Battrax
B1xx0C_
Pin 1
(Line)
Pin 3
(+VREF)
+Battrax
B2050C_
Pin 1
(Line)
Pin 2
(Ground)
Electrical Parameters
Part
Number *
B1100C_
B1160C_
B1200C_
B2050C_
VDRM
Volts
|-VREF| + |-1.2 V|
|-VREF| + |-1.2 V|
|-VREF| + |-1.2 V|
|+VREF| + |1.2 V|
VS
Volts
|-VREF| + |-10 V|
|-VREF| + |-10 V|
|-VREF| + |-10 V|
|+VREF| + |10 V|
VT
IDRM
IGT
IT
IH
CO
Volts µAmps mAmps Amps mAmps pF
4
5
100
2.2
100
50
4
5
100
2.2
160
50
4
5
100
2.2
200
50
4
5
50
2.2
50
50
* For individual “CA” and “CC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• IPP ratings assume VREF = ±48 V.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value. “CC” product is approximately 2x the listed
value.
• Positive Battrax information is preliminary data.
• VREF maximum value for the negative Battrax is -200 V.
• VREF maximum value for the positive Battrax is 110 V.
Surge Ratings
Series
A
C
IPP
2x10 µs
Amps
150
500
IPP
8x20 µs
Amps
150
400
IPP
10x160 µs
Amps
90
200
IPP
10x560 µs
Amps
60
150
IPP
10x1000 µs
Amps
50
100
ITSM
60 Hz
Amps
20
50
di/dt
Amps/µs
500
500