English
Language : 

LTL-307GW Datasheet, PDF (3/10 Pages) Lite-On Technology Corporation – Property of Lite-On Only
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical / Optical Characteristics at TA=25°C
Parameter
Symbol Min. Typ. Max. Unit Test Condition
Luminous Intensity
IV
12.6
40
IF = 20mA
mcd
Note 1,4
Viewing Angle
2θ1/2
50
deg Note 2 (Fig.6)
Peak Emission Wavelength
λP
Measurement
565
nm
@Peak (Fig.1)
Dominant Wavelength
λd
569
nm Note 3
Spectral Line Half-Width
∆λ
30
nm
Forward Voltage
VF
Reverse Current
IR
Capacitance
C
2.1
2.6
V IF = 20mA
100 µA VR = 5V
35
pF VF = 0 , f = 1MHz
Note:1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added ±15% .
Part No. : LTL-307GW
BNS-OD-C131/A4