English
Language : 

PLCVE0030240 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90-305Vac
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
LCVE-030 240
Model Name
PLCVE0030 240
SIZE
LED Power Supply
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
Module : LCVE-030 240
*(9)
SPECIFICATION
MODEL
DC OUTPUT VOLTAGE (V)
* PRESET ACCURACY (%) *(8)
* OUTPUT CURRENT(A) *(5)
* O/P NOISE (P-P, mV) *(3)
* LINE REGULATION (%) *(7)
* LOAD REGULATION (%) *(6)
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
SETUP,RISE TIME(typ.)
INPUT VOLTAGE RANGE
INPUT FREQUENCY
ACTIVE POWER FACTOR
INRUSH CURRENT (typ)
AC CURRENT
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER TEMP. PROTECTION
OVER V, PROTECTION
* OPERATING TEMP.*(4)
STORAGE TEMPERATURE
RELATIVE HUMIDITY
TEMP. COEFFICIENT
SAFETY
EMI
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
DIMENSIONS(L*W*H)
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OTP / OVP
◆ High Operating ambient Temp: -20℃ ~ +60℃
◆ Power Factor:>0.95@115Vac;>0.9@230Vac;@full load
◆ Safety: Meet UL / Meet TUV
◆ EMC: Meet CE / Meet FCC
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 134 * 42 * 33.1 mm
◆ Dimension (L*W*H): 5.28 * 1.65 * 1.3 inch
◆ ROHS Compliant
*,# =SEE NOTES BELOW
LCVE-030 240
min.
norm.
max.
24
5
1.25
300
5
5
30 W
80%
2000ms,500ms at full load 115VAC/230VAC
90-305VAC, 127-431VDC, Normal:100-277VAC
Range:47-63Hz, Normal:50-60Hz
PF>0.95 @115VAC, PF>0.9@230VAC at full load and rated output voltage
COLD START 50A @ 230VAC
0.6A/115VAC
<0.7mA/240VAC
short circuit protection will restart automatically after the fault condition is removed
shut down and latch off o/p voltage , re-power on to recover
-20 to +60℃@full load ; +80℃@60% load
-40 to +80℃
5 to +90%, non-cond.
0.03% / ℃ (0-50℃, typ)
Meet UL / Meet TUV EN 61347-2-13
Meet CE EN 55015 / Meet FCC Part15
I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
※Reference
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw