English
Language : 

LCVH-200X480 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90~305Vac OVP / OTP / OPP / SCP
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
LCVH-200 480
Model Name
PLCVH0200 480
SIZE
Power Supply
264.4 * 74 * 43.55 mm【9.7 * 2.91 * 1.71 inch】
FEATURES
◆ AC Input 90~305Vac
◆ Protection: OVP / OTP / OPP / SCP
◆ High Operating ambient Temp: -30℃~+60℃
(Refer to output dreating curve)
◆ Power Factor:>0.98@115Vac;>0.95@230Vac;@full load
◆ Safety: Meet UL / Meet TUV
◆ EMC:Meet CE / Meet FCC
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 264.4 * 74 * 43.55 mm
◆ Dimension (L*W*H): 9.7 * 2.91 * 1.71 inch
◆ ROHS Compliant
Module : LCVH-200 480
*,# =SEE NOTES BELOW
*(9)
MODEL
SPECIFICATION
min.
LCVH-200 480
norm.
max.
DC OUTPUT VOLTAGE (V)
48
* PRESET ACCURACY (%) *(8)
1
* OUTPUT CURRENT(A) *(5)
4.2
* O/P NOISE (P-P, mV) *(3)
250
* LINE REGULATION (%) *(7)
1
* LOAD REGULATION (%) *(6)
1
DC OUTPUT POWER
201.6 W
EFFICIENCY(typ @Full Load)
93%
SETUP,RISE TIME(typ.)
2S,500ms at full load 115VAC/230VAC
HOLD UP TIME
15ms at full load 115VAC/230VAC
INPUT VOLTAGE RANGE
90-305VAC, 127-431VDC, Normal:100-277VAC
INPUT FREQUENCY
Range:47-63Hz, Normal:50-60Hz
ACTIVE POWER FACTOR
PF>0.98 @115VAC, PF>0.95@230VAC at full load and rated output voltage
INRUSH CURRENT (typ)
COLD START 70A @ 230VAC
AC CURRENT
3.2A/115VAC 1.6A/230VAC
LEAKAGE CURRENT
<0.7mA/277VAC
SHORT CIRCUIT PROTECTION
short circuit protection will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OVER V, PROTECTION
shut down and latch off o/p voltage , re-power on to recover
OVER CURRENT PROTECTION
120%~160% rated output power ; Hiccup mode
* OPERATING TEMP.*(4)
-30 to +60℃(Refer to output dreating curve)
STORAGE TEMPERATURE
-40 to +80℃
RELATIVE HUMIDITY
10 to +90%, non-cond.
TEMP. COEFFICIENT
0.03% / ℃ (0-50℃, typ)
SAFETY
Meet UL60950-1 / Meet TUV EN61347-2-13
EMI
Meet CE EN55015 / Meet FCC part 15
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH
DIMENSIONS(L*W*H)
264.4 * 74 * 43.55 mm【9.7 * 2.91 * 1.71 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
※Reference
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw