LCVH-200X360 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90~305Vac OVP / OTP / OPP / SCP | |||
|
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
LCVH-200 360
Model Name
PLCVH0200 360
SIZE
Power Supply
264.4 * 74 * 43.55 mmã9.7 * 2.91 * 1.71 inchã
FEATURES
â AC Input 90~305Vac
â Protection: OVP / OTP / OPP / SCP
â High Operating ambient Temp: -30â~+60â
(Refer to output dreating curve)
â Power Factor:>0.98@115Vac;>0.95@230Vac;@full load
â Safety: Meet UL / Meet TUV
â EMC:Meet CE / Meet FCC
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Dimension (L*W*H): 264.4 * 74 * 43.55 mm
â Dimension (L*W*H): 9.7 * 2.91 * 1.71 inch
â ROHS Compliant
Module : LCVH-200 360
*,# =SEE NOTES BELOW
*(9)
MODEL
SPECIFICATION
min.
LCVH-200 360
norm.
max.
DC OUTPUT VOLTAGE (V)
36
* PRESET ACCURACY (%) *(8)
1
* OUTPUT CURRENT(A) *(5)
5.6
* O/P NOISE (P-P, mV) *(3)
200
* LINE REGULATION (%) *(7)
1
* LOAD REGULATION (%) *(6)
1
DC OUTPUT POWER
201.6 W
EFFICIENCY(typ @Full Load)
93%
SETUP,RISE TIME(typ.)
2S,500ms at full load 115VAC/230VAC
HOLD UP TIME
15ms at full load 115VAC/230VAC
INPUT VOLTAGE RANGE
90-305VAC, 127-431VDC, Normalï¼100-277VAC
INPUT FREQUENCY
Range:47-63Hz, Normalï¼50-60Hz
ACTIVE POWER FACTOR
PF>0.98 @115VAC, PF>0.95@230VAC at full load and rated output voltage
INRUSH CURRENT (typ)
COLD START 70A @ 230VAC
AC CURRENT
3.2A/115VAC 1.6A/230VAC
LEAKAGE CURRENT
<0.7mA/277VAC
SHORT CIRCUIT PROTECTION
short circuit protection will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OVER V, PROTECTION
shut down and latch off o/p voltage , re-power on to recover
OVER CURRENT PROTECTION
120%~160% rated output power ; Hiccup mode
* OPERATING TEMP.*(4)
-30 to +60â(Refer to output dreating curve)
STORAGE TEMPERATURE
-40 to +80â
RELATIVE HUMIDITY
10 to +90%, non-cond.
TEMP. COEFFICIENT
0.03% / â (0-50â, typ)
SAFETY
Meet UL60950-1 / Meet TUV EN61347-2-13
EMI
Meet CE EN55015 / Meet FCC part 15
WITHSTAND VOLTAGE
I/P-O/Pï¼3.75KVAC, O/P-Grndï¼0.5KVAC, I/P-Grndï¼1.88KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25â / 70% RH
DIMENSIONS(L*W*H)
264.4 * 74 * 43.55 mmã9.7 * 2.91 * 1.71 inchã
NOTESï¼(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25â, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
â»Reference
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
|
▷ |