LCCH-080X420 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90~305Vac SCP / OTP / OVP
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
LCCH-080 420
Model Name
PLCCH0080 420
SIZE
Power Supply
208.4 * 72 * 38.55 mm【8.2 * 2.83 * 1.52 inch】
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OTP / OVP
◆ High Operating ambient Temp: -30℃~+60℃
(Refer to output dreating curve)
◆ Power Factor:>0.98@115Vac;>0.95@230Vac;@full load
◆ Safety: UL
◆ EMC: Meet CE
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 208.4 * 72 * 38.55 mm
◆ Dimension (L*W*H): 8.2 * 2.83 * 1.52 inch
◆ ROHS Compliant
Module : LCCH-080 420
*(9)
SPECIFICATION
MODEL
DC OUTPUT VOLTAGE RANGE (V)
* PRESET ACCURACY (%) *(8)
* OUTPUT CURRENT(A) *(5)
* O/P NOISE (P-P, mV) *(3)
* LINE REGULATION (%) *(7)
* LOAD REGULATION (%) *(6)
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
SETUP,RISE TIME(typ.)
HOLD UP TIME
INPUT VOLTAGE RANGE
INPUT FREQUENCY
ACTIVE POWER FACTOR
INRUSH CURRENT (typ)
AC CURRENT
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER TEMP. PROTECTION
OVER V, PROTECTION
* OPERATING TEMP.*(4)
STORAGE TEMPERATURE
RELATIVE HUMIDITY
TEMP. COEFFICIENT
SAFETY
EMI
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
DIMENSIONS(L*W*H)
*,# =SEE NOTES BELOW
LCCH-080 420
min.
nrom.
max.
36
42
1
1.9
500
1
1
79.8 W
90%
2S,500mS at full load 115VAC/230VAC
25ms at full load 115VAC/230VAC
90-305VAC, 127-431VDC, Normal:100-277VAC
Range:47-63Hz, Normal:50-60Hz
PF>0.95 @230VAC, PF>0.98@115VAC at full load and rated output voltage
COLD START 65A @ 230VAC
1.5A/115VAC 0.56A/230VAC
<0.45mA/277VAC
short circuit protection will restart automatically after the fault condition is removed
shut down and latch off o/p voltage , re-power on to recover
-30 to +60℃@full load( Refer to output derating curve)
-40 to +80℃
10 to +90%, non-cond.
0.03% / ℃ (0-50℃, typ)
UL60950-1
Meet CE EN55015
I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH
208.4 * 72 * 38.5 mm【8.2 * 2.83 * 1.52 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.