English
Language : 

LCCE-017X501 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90~305Vac SCP / OTP / OVP
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
LCCE-017 501
Model Name
PLCCE0017 501
SIZE
Constant Current Power Supply
95 * 40 * 25 mm 【3.74 * 1.57 * 0.98 inch】
Module : LCCE-017 501
*(8)
SPECIFICATION
MODEL
DC OUTPUT VOLTAGE (V)
* PRESET ACCURACY (%) *(7)
* OUTPUT CURRENT(A) *(5)
* O/P NOISE (P-P, V) *(3)
* LINE REGULATION (%) *(6)
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
TURN ON DELAY TIME
INPUT VOLTAGE RANGE
INPUT FREQUENCY
INRUSH CURRENT (typ)
AC CURRENT
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER TEMP. PROTECTION
OVER V, PROTECTION
* OPERATING TEMP.*(4)
STORAGE TEMPERATURE
RELATIVE HUMIDITY
TEMP. COEFFICIENT
SAFETY
EMI
DIMENSIONS(L*W*H)
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OTP / OVP
◆ High Operating ambient Temp: -20℃ ~ +60℃
◆ Power Factor: >0.95@115VAC
◆ Safety: UL
◆ EMC: CE / FCC
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension(L*W*H): 95 * 40 * 25 mm
◆ Dimension(L*W*H): 3.74 * 1.57 * 0.98 inch
◆ ROHS Compliant
*,# =SEE NOTES BELOW
LCCE-017 501
min.
norm.
max.
36
10
0.5
3.5
10
18 W
82%
3000ms at full load 115VAC/230VAC
90-305VAC, 127-431VDC, Normal:100-277VAC
Range:47-63Hz, Normal:50-60Hz
COLD START 5A @ 230VAC
0.4A/110VAC
<0.7mA/264VAC
The SCP will restart automaticalty after the fault condition is removed.
The power will derate on the current limit.
The OVP is latched shutdown mode.
-20 to +60℃@full load
-40 to +80℃
10 to +90%
0.03% / ℃ (0-50℃, typ)
UL 60950-1
CE EN55015 / FCC Part15
95 * 40 * 25 mm 【3.74 * 1.57 * 0.98 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Line regulation measured from 100VAC to 277VAC.
(7)Preset accuracy measured at normal load, 120VAC input.
(8)100% Production Tested.
※Reference www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw