English
Language : 

LAL2100-50 Datasheet, PDF (1/1 Pages) LinkCom Manufacturing Co., Ltd. – Broadband Access Transformer
LAL2100-50
Broadband Access Transformer
z Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
z RoHS Compliant
z Operating Temperature -40°C to 85°C
OCL:
Leakage
Indutance:
D.C.R
Turn Ratio:
T.H.D
Hi-POT :
Electrical Specifications @25
PIN 16-9= 400uH ±10% @ 10KHz/0.1V (PIN11-14 Short)
PIN 16-9= 3.0uH Max. @ 100KHz/0.1V (PIN11-14,PIN1-2-3-4 Short)
PIN 16-9= 2.0uH Max. @ 100KHz/0.1V (PIN11-14,PIN5-6-7-8 Short)
PIN 1-4 = 0.3 ohm Max. (PIN1-2,PIN3-4 Short)
PIN 5-8 = 4.4 ohm Max. (PIN6-7 Short)
PIN 16-9 = 3.0 ohm Max. (PIN11-14 Short)
PIN16-9 : PIN 1-4 = 4.25±3% :1 (PIN11-14,PIN1-2,PIN 3-4 Short)
PIN16-9 : PIN 5-8 = 1±3% :1 (PIN11-14,PIN6-7 Short)
PIN16-9 - PIN5-8 = -82dB Max. @ 30KHz/3.162V (PIN11-14,PIN6-7 Short)
Pri. - Sec. =1875V/60Hz/2Sec/1mA
Dimensions (Units: mm)
3.4±0.3
5.1±0.3
0.7TYP.
****
LinkCom F
X DATE CODE G
0.5TYP.
13.5±0.5
G
1.7±0.3
PIN1
A
12.6±0.5
5.10
3.40
3.40
1.70
A
2- 1.5 +0.15
-0.10
A
1.70
1.00
'A' MEANS THROUGH HOLE
SUGGESTED PAD LAYOUT
C
13.5±0.5
B
1.2±0.1
D
10.9±0.2
13.0±0.5
15.5±0.5
E 17.0+1.0/-0.5
Schematic
1
Tx
3
2
4
5
Rx
7
6
8
SEC
PRI
16
11
LINE
14
9
Mark
1.LAL****----LAL2100
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS
Rev. A