LAL2021-50
Broadband Access Transformer
z Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
z RoHS Compliant
z Operating Temperature -40°C to 85°C
OCL:
Leakage
Inductance:
Interwinding
Capacitance
T.H.D
D.C.R
Hi-POT :
Turn Ratio:
Electrical Specifications @25
PIN 16-9= 100uH ±5% @ 10KHz/0.1V/Ser. (PIN 11-14 Short)
PIN 16-9= 3.5uH Max. @ 100KHz/0.1V (PIN 1-2-3-4-5-6-7-8,11-14 Short)
PIN 1-16= 50 pF Max. @ 100KHz/0.1V (PIN 1-2-3-4-5-6-7-8,PIN 11-14 Short)
PIN 1-4 to PIN 16-9= -85dB Max. @ 100KHz/4V (PIN 2-3,PIN 11-14 Short)
PIN 5-8 to PIN 16-9= -85dB Max. @ 100KHz/4V (PIN 6-7,PIN 11-14 Short)
PIN 1-4 = 0.840 ohm Max. (PIN 2-3 Short)
PIN 5-8 = 0.250 ohm Max. (PIN 6-7 Short)
PIN 16 -9 = 0.420 ohm Max. (PIN 11-14 Short)
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1 ( PIN 11-14,PIN 2-3 Short)
PIN16-9 : PIN 5-8 = 4.25±2% :1 ( PIN 11-14,PIN 6-7 Short)
Dimensions (Units: mm)
Schematic
LALXXXX
LinkCom
X Date Code G
DOT PIN1
SUGGESTED PADS LAYOUT
Rev.B
Mark
1.LAL****----LAL2021
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS