English
Language : 

LAL0680-51 Datasheet, PDF (1/1 Pages) LinkCom Manufacturing Co., Ltd. – Broadband Access Transformer
LAL0680-51
Broadband Access Transformer
z Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
z RoHS Compliant
z Operating Temperature -40°C to 85°C
OCL:
Leakage
Indutance:
Interwinding
Capacitance
T.H.D
D.C.R
Hi-POT :
Turn Ratio:
Electrical Specifications @25℃
PIN 1-4= 1.5mH ±5% @ 10KHz/0.1V/Ser. (PIN 2-3 Short)
PIN 1-4= 8.0±2 uH @ 100KHz/0.1V (PIN 2-3, 7-8-9-10 Short)
PIN 1-10= 30±7 pF @ 100KHz/0.1V (PIN 2-3, 8-9 Short)
-87dB Max. @ 30KHz/3.162V
PIN 1-3 = 810 mohm ±10%
PIN 2-4 = 810 mohm ±10%
PIN 7-9 = 200 mohm ±10%
PIN 8-10 = 200 mohm ±10%
PIN 1-4 - PIN 10-7 =1875VAC/60Hz/2Seconds/1mA (PIN 2-3,8-9 Short)
PIN1-4 : PIN 10-7 = 2.0±2% :1 (PIN 2-3, 8-9 Short)
Dimensions (Units: mm)
0.7TYP.
1.80
LAL****
LinkCom H
X Date Code G
13.4±0.5
G
A
12.6±0.5
PIN1
2.5
PIN1
SUGGESTED PAD LAYOUT
C
13.5±0.5
B
2.5REF
I
D
13.0±0.5
E
15.5±0.5
F 17 0 +1.0
Rev: A
Schematic
1
10
3
8
2
9
4
7
Mark
1.LAL****----LAL0680
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS