English
Language : 

BPCE030C701_14 Datasheet, PDF (1/2 Pages) LinkCom Manufacturing Co., Ltd. – AC Input 90~264Vac Protection: OVP / OTP / SCP
Model NO.
Part NO.
LinkCom Manufacturing Co., Ltd
BPCE030C701
Model Name
PLKBPCE030C701
SIZE
LED Power Supply
152 * 53 * 39.5 mm【5.98 * 2.09 * 1.56 inch】
Module : BPCE030C701
*(9)
SPECIFICATION
MODEL
DC OUTPUT VOLTAGE RANGE (V)
* PRESET ACCURACY (%) *(8)
* OUTPUT CURRENTRANGE (A) *(5)
* O/P NOISE (P-P, V) *(3)
* LINE REGULATION (%) *(7)
* LOAD REGULATION(%) *(6)
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
TURN ON DELAY TIME
INPUT VOLTAGE RANGE
INPUT FREQUENCY
INRUSH CURRENT (typ)
AC CURRENT
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER TEMP. PROTECTION
OVER V, PROTECTION
* OPERATING TEMP.*(4)
STORAGE TEMPERATURE
RELATIVE HUMIDITY
TEMP. COEFFICIENT
SAFETY
EMI
DIMENSIONS(L*W*H)
FEATURES
◆ AC Input 90~264Vac
◆ Protection: OVP / OTP / SCP
◆ High Operating ambient Temp: -20℃ ~ +60℃
◆ Power Factor: >0.95@115Vac / >0.9@230Vac
◆ Safety: TUV / CB / PSE
◆ EMC: CE
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 152 * 53 * 39.5 mm
◆ Dimension (L*W*H): 5.98 * 2.09 * 1.56 inch
◆ ROHS Compliant
*,# =SEE NOTES BELOW
BPCE030C701
min.
norm.
max.
32
42
10
0.63
0.77
2.6
10
10
29.4 W
85%
3000ms at full load 115VAC/230VAC
90-264VAC, 127-373VDC, Normal:100-240VAC
Range:47-63Hz, Normal:50-60Hz
COLD START 50A @ 230VAC
0.5A/115VAC
0.5mA/264VAC
SCP, OTP, OVP will restart automatically after the fault condition is removed
-20 to +60℃@full load
-40 to +80℃
10 to +90%
0.03% / ℃ (0-50℃, typ)
TUV EN 61347-2-13 / CB / PSE
CE EN55015
152 * 53 * 39.5 mm【5.98 * 2.09 * 1.56 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 240VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
※Reference www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw