75W-LCCEA Datasheet, PDF (1/4 Pages) LinkCom Manufacturing Co., Ltd. – 75W Power Supply | |||
|
75-LCCEA Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
75W Power Supply
Constant Current Mode
FEATURES:
â AC Input 100~277 Vac Nominal
â Built-in Active Power Factor Correction
â Protection: SCP / OVP / OTP
â High Operating Ambient Temp.: -30 â ~ +55 â
â Surge Protection: L-N 6 kV
â Safety: Meets UL 8750
â EMI: Meets FCC / Meets CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty: 5 years @ T.C < 75 â (refer to LinkCom warranty policy)
â RoHS Compliant
PRODUCT SPECIFICATION
MODEL
LCCEA075U480-00
LCCEA075U320-00
LCCEA075U360-00
LCCEA075U240-00
DC OUTPUT
POWER(W)
75
75
75
75
DC OUTPUT
VOLTAGE(V)
36~48
32~42
28-36
18-24
OUTPUT
CURRENT(A)
1.6
1.8
2.1
3.2
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
89.0%
89.0%
88.0%
88.0%
0.48 V
0.42 V
0.36 V
0.24 V
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47 - 63 Hz, Normal: 50 - 60 Hz
ACTIVE POWER FACTOR
> 0.9 @ Full Load 100-277 Vac
THD
< 20 % at Full Load 100 - 277 Vac
TURN ON DELAY TIME
< 1 s at Full Load 100 - 277 Vac
AC CURRENT
1 A / 100 Vac 0.3 A / 277 Vac
INRUSH CURRENT (typ)
Cold Start 65 A @ 230 Vac
LEAKAGE CURRENT
< 0.75 mA
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
SCP and OVP will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
shut down and latch off o/p voltage , re-power on to recover
OVER CURRENT PROTECTION
120% ~ 160% rated output power ; Hiccup mode
OPERATING TEMP.
-30â ~ +55 â @ Full Load 100 - 277 Vac
STORAGE TEMP.
-40â ~ +80â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 8750
EMI
Meets FCC Part15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/Pï¼3.75 kVac, O/P-Grndï¼0.5 kVac, I/P-Grndï¼1.88 kVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG: 100M Ω / 500 Vdc / 25â / 70% RH
DIMENSION (L*W*H)
232 * 46.5 * 31 mmã9.13 * 1.83 * 1.22 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |