60W-LCCEA Datasheet, PDF (1/4 Pages) LinkCom Manufacturing Co., Ltd. – 60W LED Power Supply | |||
|
60-LCC Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
60W LED Power Supply
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
LCCEA060U132-00
LCCEA060U142-00
LCCEA060U172-00
LCCEA050U432-00
FEATURES:
â AC Input 90~305 Vac Nominal
â Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac @ Full Load
â Protection: SCP / OVP / OCP
â High Operating Ambient Temp.: -20â ~ +60â
â Surge Protection: L-N 1 kV, L/N-FG 2 kV
â Safety: UL
â EMI: Meets FCC / Meets CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty: 5 years (refer to LinkCom warranty policy)
â RoHS Compliant
DC OUTPUT
POWER(W)
62.4
58.8
61.2
51.6
DC OUTPUT
VOLTAGE(V)
42-48
33-42
33-36
9-12
OUTPUT
CURRENT(A)
1.3
1.4
1.7
4.3
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
86%
4.6
86%
4.2
86%
3.6
84%
2
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load
THD
< 20% @ 277 Vac Full Load
TURN ON DELAY TIME
3 s at Full Load 115 Vac / 230 Vac
AC CURRENT
0.8 A / 115 Vac 0.4 A / 230 Vac
INRUSH CURRENT (Max.)
Cold Start 50 A @ 230 Vac
LEAKAGE CURRENT
0.75 mA / 132 Vac / 60 Hz
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
SCP, OVP and OTP will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OVER CURRENT PROTECTION
NA
OPERATING TEMP.
-20â ~ +60â
STORAGE TEMP.
-40â ~ +80â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL 8750
EMI
Meets FCC Part15 / Meets CE EN55015
WITHSTAND VOLTAGE
NA
ISOLATION RESISTANCE
NA
DIMENSION (L*W*H)
158 * 58 * 39.4 mm ã6.22 * 2.28 * 1.55 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |