English
Language : 

60W-DBFE Datasheet, PDF (1/5 Pages) LinkCom Manufacturing Co., Ltd. – 0-10V Dimmable
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
0-10V Dimmable
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
FEATURES:
● AC Input 90~305 Vac Nominal
● Built-in Active Power Factor Correction
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -20℃~+60℃
● THD: <20% @ 277VAC Full Load
● Surge Protection: L-N 1 kV, L/N-FG 2 kV
● Safety: UL
● EMI: Meets CE / Meets FCC
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 3 years (refer to LinkCom warranty policy)
● 0-10V dimming
● RoHS Compliant
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
OUTPUT
CURRENT(A)
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY
O/P NOISE
(pk-pk,V)
DBFE0060U132
DBFE0060U142
DBFE0060U152
DBFE0060U172
DBFE0060U212
DBFE0060U252
DBFE0050U432
62.4
42-48V
1.3
58.8
33-42V
1.4
60.0
30-40V
1.5
61.2
30-36V
1.7
63.0
24-30V
2.1
60.0
19-24V
2.5
51.6
9-12V
4.3
±5%
86%
4.6V
±5%
86%
4.2V
±5%
86%
4V
±5%
86%
3.6V
±5%
86%
3.6V
±5%
86%
2.7V
±5%
82%
2V
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63Hz, Normal: 50-60Hz
ACTIVE POWER FACTOR
> 0.95 @ 110 Vac; > 0.9 @ 230 Vac
THD
< 20% at Full Load 100-277 Vac
TURN ON DELAY TIME
3000 ms at Full Load 115 Vac / 230 Vac
AC CURRENT
0.8 A / 110 Vac; 0.4 A / 230 Vac
INRUSH CURRENT (typ)
Cold Start 50 A @ 230 Vac
LEAKAGE CURRENT
< 0.75 mA at 277 Vac
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
automatically after the fault condition is removed
OVER TEMP. PROTECTION
OPERATING TEMP.
-20℃ ~ +60 ℃ @ Full Load 110-277 Vac
STORAGE TEMP.
-40 ℃ ~ +80 ℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL 8750
EMI
Meets FCC Part15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P:4242 Vdc, I/P-FG:2500 Vdc,I/P-CASE : 2500 Vdc
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG : >10M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
158 * 58 * 39.4 mm【6.22 * 2.28 * 1.55 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw