English
Language : 

40W-DBFE Datasheet, PDF (1/5 Pages) LinkCom Manufacturing Co., Ltd. – 0-10V Dimmable
45-DBFE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
0-10V Dimmable
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
DBFE-045U172-00
DBFE-045U192-00
FEATURES:
● AC Input 90~305 Vac Nominal
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -20℃~+60℃
● Power Factor: > 0.95 @ 115 VAC / > 0.9 @ 277 VAC
● T.H.D: <20%
● Surge Protection: L-N 1 kV, L/N-FG 2 kV
● Safety: Meets UL
● EMI: Meets CE / Meets FCC
● Surge: Line to Line 2 kV; Line to FG 4kV
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
DC OUTPUT
POWER(W)
42
45.6
DC OUTPUT
VOLTAGE(V)
14-24
14-24
OUTPUT
CURRENT(A)
1.75
1.9
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
84%
2.5
84%
2.5
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 115 Vac / > 0.9 @ 277 Vac
THD
< 20%
TURN ON DELAY TIME
3000 ms at Full Load 115 Vac / 230 Vac
AC CURRENT
0.7 A / 100 Vac
INRUSH CURRENT (typ)
COLD START 43 A @ 230 Vac
LEAKAGE CURRENT
0.75 mA / 264 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVP will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OTP will restart automatically after the fault condition is removed
OVER CURRENT PROTECTION
NA
OPERATING TEMP.
-20℃ ~ +60 ℃ @ Full Load
STORAGE TEMP.
-40℃ ~ +80℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part15 / Meets EN55015
WITHSTAND VOLTAGE
I/P-O/P: 4.242 kVdc , I/P-FG: 2.5 kVdc, I/P-CASE: 2.5 kVdc
ISOLATION RESISTANCE
I/P-O/P: 100M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
163 * 47 * 31.6 mm 【6.42 * 1.85 * 1.24 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw