30-LCVE Datasheet, PDF (1/3 Pages) LinkCom Manufacturing Co., Ltd. – 30W LED Power Supply | |||
|
30-LCVE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
30W LED Power Supply
Constant Voltage Mode
PRODUCT SPECIFICATION
MODEL
LCVE-030U125-00
LCVE-030U240-00
FEATURES:
â AC Input 90~305 Vac Nominal
â AC Inrush current: 50 A @ 230 Vac Cold start
â Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac
â Protection: SCP / OVP / OTP / OCP
â High Operating Ambient Temp.: -20 â ~ +60 â
â Surge Protection: L-N 1 kV, L/N-FG 2 kV
â Safety: Meets UL
â EMI: Meets FCC / Meets CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty: 5 years (refer to LinkCom warranty policy)
â RoHS Compliant
DC OUTPUT
POWER(W)
30
30
DC OUTPUT
VOLTAGE(V)
12
24
OUTPUT
CURRENT(A)
2.5
1.25
OUTPUT
VOLTAGE
TOLERANCE
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
81%
0.3
81%
0.3
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load and Rated Output Voltage
THD
NA
TURN ON DELAY TIME
2000 ms, 500 ms at Full Load 115 Vac / 230 Vac
AC CURRENT
0.6 A / 115 Vac
INRUSH CURRENT (typ)
Cold Start 50 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER CURRENT PROTECTION
OCP will restart automatically after the fault condition is removed
OPERATING TEMP.
-20 â ~ +60 â
STORAGE TEMP.
-40 â ~ +80 â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P: 4.242 kVdc I/P-CASE: 4 kVdc
ISOLATION RESISTANCE
I/P-O/P: 100M Ω / 500 Vdc / 25â / 70% RH
DIMENSION (L*W*H)
134 * 42 * 33.1 mmã5.28 * 1.65 * 1.3 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |