30-LCVE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
30W LED Power Supply
Constant Voltage Mode
PRODUCT SPECIFICATION
MODEL
LCVE-030U125-00
LCVE-030U240-00
FEATURES:
● AC Input 90~305 Vac Nominal
● AC Inrush current: 50 A @ 230 Vac Cold start
● Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac
● Protection: SCP / OVP / OTP / OCP
● High Operating Ambient Temp.: -20 ℃ ~ +60 ℃
● Surge Protection: L-N 1 kV, L/N-FG 2 kV
● Safety: Meets UL
● EMI: Meets FCC / Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
DC OUTPUT
POWER(W)
30
30
DC OUTPUT
VOLTAGE(V)
12
24
OUTPUT
CURRENT(A)
2.5
1.25
OUTPUT
VOLTAGE
TOLERANCE
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
81%
0.3
81%
0.3
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load and Rated Output Voltage
THD
NA
TURN ON DELAY TIME
2000 ms, 500 ms at Full Load 115 Vac / 230 Vac
AC CURRENT
0.6 A / 115 Vac
INRUSH CURRENT (typ)
Cold Start 50 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER CURRENT PROTECTION
OCP will restart automatically after the fault condition is removed
OPERATING TEMP.
-20 ℃ ~ +60 ℃
STORAGE TEMP.
-40 ℃ ~ +80 ℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P: 4.242 kVdc I/P-CASE: 4 kVdc
ISOLATION RESISTANCE
I/P-O/P: 100M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.