25W-LCCE Datasheet, PDF (1/4 Pages) LinkCom Manufacturing Co., Ltd. – 25W Constant Current Power Supply | |||
|
25-LCCE Series
www.linkcom.com.tw For more information, please FcoEntAacTt wUitRh: EsaSle:s@linkcom.com.tw
25W Constant Current Power Supply
Constant Current Mode
â AC Input 90~305Vac Nominal
â AC Inrush current: 10A @ 230 Vac Cold start
â Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac
â Protection: SCP / OVP / OCP
â High Operating Ambient Temp.: -20â~+60â
â Surge Protection: L-N 0.5 kV
â Safety: UL / CB / PSE
â EMI: FCC / CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty: 5 years (refer to LinkCom LinkCom warranty policy)
â RoHS Compliant
PRODUCT SPECIFICATION
MODEL
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
OUTPUT
CURRENT(A)
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY O/P NOISE(P-P,V)
LCCE-025U122-00
25.2
15-21
1.2
±5%
80%
4
LCCE-025U112-00
25.2
18-24
1.05
±5%
83%
3
LCCE-025U701-00
27.36
30-37
0.72
±5%
83%
3
LCCE-025U801-00
21
24-30
0.7
±5%
80%
2
LCCE-025U901-00
21.6
18-24
0.9
±5%
80%
2
LCCE-030U831-00
29.88
30-36
0.83
±5%
83%
3
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63Hz, Normal: 50-60Hz
ACTIVE POWER FACTOR
> 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load and Rated Output Voltage
THD
NA
TURN ON DELAY TIME
NA
AC CURRENT
0.4 A / 115 Vac 0.2 A / 230 Vac
INRUSH CURRENT (Max)
Cold Start 10 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER TEMP. PROTECTION
NA
OVER CURRENT PROTECTION
Constant Current
OPERATING TEMP.
-20â~+60â
STORAGE TEMP.
-40â~+80â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL60950-1 / CB 61347-2-13/ PSE
EMI
EN 55015/ FCC PART 15
WITHSTAND VOLTAGE
NA
ISOLATION RESISTANCE
NA
DIMENSION (L*W*H)
134 * 42 * 33.1 mmã5.28 *1.65 * 1.3 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |