English
Language : 

25W-DBFE Datasheet, PDF (1/5 Pages) LinkCom Manufacturing Co., Ltd. – 0-10V Dimmable
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
0-10V Dimmable
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
DBFE-025U701-00
DBFE-020U701-00
FEATURES:
● AC Input 108~305 Vac Nominal
● 1-10V Dimming
● AC Inrush current: 10 A @ 230 Vac Cold start
● Power Factor: > 0.95 @ 120 Vac / > 0.9 @ 277 Vac
● Protection: SCP / OVP / OCP
● High Operating Ambient Temp.: -30 ℃ ~ +60 ℃
● Surge Protection: L-N 2 kV
● Safety: Meets UL
● EMI: Meets FCC / Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
DC OUTPUT
POWER(W)
26.6
19.6
DC OUTPUT
VOLTAGE(V)
30-38
20-28
OUTPUT
CURRENT(A)
0.7
0.7
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
84%
3
84%
3
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
108-305 Vac, 152-431 Vdc, Normal: 120-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 120 Vac / > 0.9 @ 277 Vac
THD
< 20% @ 277 Vac at Full Load
TURN ON DELAY TIME
1s at Full Load 120 Vac / 277 Vac
AC CURRENT
0.35 A / 120 Vac 0.15 A / 277 Vac
INRUSH CURRENT (max)
Cold Start 10 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER CURRENT PROTECTION
Constant Current
OPERATING TEMP.
-30℃~+60℃
STORAGE TEMP.
-40℃~+80℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P: 3 kVac
ISOLATION RESISTANCE
I/P-O/P :10M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
134 * 42 * 33.1 mm【5.28 *1.65 * 1.3 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw