25W-DBFE Datasheet, PDF (1/5 Pages) LinkCom Manufacturing Co., Ltd. – 0-10V Dimmable | |||
|
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
0-10V Dimmable
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
DBFE-025U701-00
DBFE-020U701-00
FEATURES:
â AC Input 108~305 Vac Nominal
â 1-10V Dimming
â AC Inrush current: 10 A @ 230 Vac Cold start
â Power Factor: > 0.95 @ 120 Vac / > 0.9 @ 277 Vac
â Protection: SCP / OVP / OCP
â High Operating Ambient Temp.: -30 â ~ +60 â
â Surge Protection: L-N 2 kV
â Safety: Meets UL
â EMI: Meets FCC / Meets CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty: 5 years (refer to LinkCom warranty policy)
â RoHS Compliant
DC OUTPUT
POWER(W)
26.6
19.6
DC OUTPUT
VOLTAGE(V)
30-38
20-28
OUTPUT
CURRENT(A)
0.7
0.7
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
84%
3
84%
3
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
108-305 Vac, 152-431 Vdc, Normal: 120-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 120 Vac / > 0.9 @ 277 Vac
THD
< 20% @ 277 Vac at Full Load
TURN ON DELAY TIME
1s at Full Load 120 Vac / 277 Vac
AC CURRENT
0.35 A / 120 Vac 0.15 A / 277 Vac
INRUSH CURRENT (max)
Cold Start 10 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER CURRENT PROTECTION
Constant Current
OPERATING TEMP.
-30â~+60â
STORAGE TEMP.
-40â~+80â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P: 3 kVac
ISOLATION RESISTANCE
I/P-O/P :10M Ω / 500 Vdc / 25â / 70% RH
DIMENSION (L*W*H)
134 * 42 * 33.1 mmã5.28 *1.65 * 1.3 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |