English
Language : 

200W-LCCH Datasheet, PDF (1/3 Pages) LinkCom Manufacturing Co., Ltd. – 200W Power Supply
200-LCCH Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
200W Power Supply
Constant Current Mode
FEATURES:
● AC Input 90~305 Vac Nominal
● Power Factor: > 0.98 @ 100 Vac / > 0.95 @ 230 Vac
● Protection: SCP / OVP / OTP / OCP
● High Operating Ambient Temp.: -30℃ ~ +60℃(refer to dreating curve)
● Surge Protection: L-N 2 kV, L/N-FG 4 kV
● Safety: PSE
PRODUCT SPECIFICATION
MODEL
LCCH-200U120-00
LCCH-200U240-00
LCCH-200U360-00
LCCH-200U420-00
LCCH-200U480-00
● EMI: Meets FCC / Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
DC OUTPUT
POWER(W)
192
201.6
201.6
201.6
201.6
DC OUTPUT
VOLTAGE(V)
8-12
18-24
27-36
32-42
36-48
OUTPUT
CURRENT(A)
16
8.4
5.6
4.8
4.2
OUTPUT
VOLTAGE
TOLERANCE
±5%
±5%
±5%
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
90%
0.5
92%
0.5
92%
0.8
92%
0.8
92%
0.8
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.98 @ 110 Vac / > 0.95 @ 230 Vac at Full Load and Rated Output Voltage
THD
NA
TURN ON DELAY TIME
< 3s at Full Load 100-277 Vac
AC CURRENT
3.2 A / 110 VAC
INRUSH CURRENT (typ)
cold start 70 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 277 Vac
SHORT CIRCUIT PROTECTION
short circuit protection will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
restart automatically after the fault condition is removed
OPERATING TEMP.
-30℃ ~ +60℃(refer to dreating curve)
STORAGE TEMP.
-40℃~+80℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
PSE
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P:3.75 kVac, O/P-Grnd:0.5 kVac, I/P-Grnd:1.88 kVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
246.4 * 74 * 43.55 mm【9.7 * 2.91 * 1.71 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw