English
Language : 

100W-LCCH Datasheet, PDF (1/4 Pages) LinkCom Manufacturing Co., Ltd. – 100W LED Power Supply
100-LCCH Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
100W LED Power Supply
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
LCCH-100U120-00
LCCH-100U240-00
LCCH-100U300-00
LCCH-100U360-00
LCCH-100U480-00
FEATURES:
● AC Input 90~305 Vac Nominal
● Power Factor: > 0.98 @ 115 Vac / > 0.95 @ 230 Vac at full load
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -30 ℃ ~ +70 ℃ (refer to dreating curve)
● Surge: L-N 2 kV, L/N-FG 4 kV
● Safety: UL / CB / PSE
● EMI: CE / FCC
● Comply with Indoor / Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
DC OUTPUT
POWER(W)
100.8
100.8
102
100.8
100.8
DC OUTPUT
VOLTAGE(V)
8-12
18-24
24-30
30-36
40-48
OUTPUT
CURRENT(A)
8.4
4.2
3.4
2.8
2.1
OUTPUT
CURRENT
TOLERANCE
±5%
±5%
±5%
±5%
±5%
EFFICIENCY O/P NOISE(P-P,V)
88%
0.5
90%
0.5
91%
0.5
91%
0.5
91%
0.5
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127- 431 Vdc, Normal: 120-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
>0.98 @ 115 Vac / > 0.95 @ 230 Vac at Full Load and Rated Output Voltage
THD
< 20% @ 277 Vac full load
TURN ON DELAY TIME
<1s at Full Load 120-277 Vac
AC CURRENT
1.7 A / 115 Vac 0.65 A / 230 Vac
INRUSH CURRENT (Max)
Cold Start 65 A @ 230 Vac
LEAKAGE CURRENT
< 0.45 mA / 264 Vac
SHORT CIRCUIT PROTECTION
short circuit protection will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
shut down and latch off o/p voltage , re-power on to recover
OVER CURRENT PROTECTION
constand current
OPERATING TEMP.
-30 ℃ ~ +70 ℃ (refer to dreating curve)
STORAGE TEMP.
-40 ℃ ~ +80 ℃
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL60950-1 / CB 61347-2-13 / PSE
EMI
EN 55015/ FCC PART 15
WITHSTAND VOLTAGE
I/P-O/P: 3 kVac, O/P-Grnd: 1.5 kVac, I/P-Grnd: 1.5 kVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG: 100M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
208.4 * 72 * 38.5 mm【8.2 * 2.83 * 1.52 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw