100W-LCCEA Datasheet, PDF (1/4 Pages) LinkCom Manufacturing Co., Ltd. – 100W Power Supply | |||
|
100-LCCEA Series
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
100W Power Supply
Constant Current Mode
PRODUCT SPECIFICATION
MODEL
LCCEA100U240-00
LCCEA100U360-00
LCCEA100U420-00
LCCEA100U480-00
FEATURES:
â AC Input 90~305 Vac Nominal
â Built-in Active Power Factor Correction
â Protection: SCP / OVP / OTP / OCP
â High Operating Ambient Temp.: -30 â ~ +50 â
â Surge Protection: L-N 6 kV
â Safety: UL
â EMI: FCC / Meets CE
â Comply with Indoor/Outdoor Waterproof (IP 67)
â Warranty:5 years (refer to LinkCom warranty policy)
â RoHS Compliant
DC OUTPUT
POWER(W)
96
96
96
96
DC OUTPUT
VOLTAGE(V)
18-24
28-36
32-42
36-48
OUTPUT
CURRENT(A)
4
2.7
2.3
2
OUTPUT
CURRENT
TOLERANCE
±3%
±3%
±3%
±3%
EFFICIENCY O/P NOISE(P-P,V)
88%
88.5%
89%
89%
1% Vo(max.)
1% Vo(max.)
1% Vo(max.)
1% Vo(max.)
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.9 @ Full Load 100-277 Vac
THD
< 20% at 80%-Full Load 100-277 Vac
TURN ON DELAY TIME
< 1s at Full Load 100-277 Vac
AC CURRENT
1.5 A / 100 Vac 0.6 A / 277 Vac
INRUSH CURRENT (Max.)
Cold Start 65 A @ 230 Vac
LEAKAGE CURRENT
< 0.75 mA
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
SCP and OVP will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
shut down and latch off o/p voltage , re-power on to recover
OVER CURRENT PROTECTION
120%~160% rated output power ; Hiccup mode
OPERATING TEMP.
-30 â ~ +50 â @ Full Load 100-277 Vac
STORAGE TEMP.
-40 â ~ +80 â
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL 8750
EMI
FCC Part15 / Meets EN55015
WITHSTAND VOLTAGE
I/P-O/P: 3.75 kVac, O/P-Grnd: 0.5 kVac, I/P-Grnd: 1.88 kVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ω / 500 Vdc / 25â / 70% RH
DIMENSION (L*W*H)
232 * 46.5 * 31 mmã9.13 * 1.83 * 1.22 inchã
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical @25â, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
ï¼REFERENCE: www.linkcom.com.tw
ï¼Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ⪠T: +886-2-8919-1380 ⪠F: +886-2-8919-1370 ⪠www.linkcom.com.tw
|
▷ |