English
Language : 

RH6200M_15 Datasheet, PDF (4/10 Pages) Linear Technology – Low Noise, High Speed Rail-to-Rail Op Amp
RH6200M
TABLE 2: ELECTRICAL TEST
REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group B and D for Class S,
End Point Electrical Parameters (Method 5005)
*PDA applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*, 2, 3, 4, 5, 6
1*, 2, 3, 4, 5, 6
1, 2, 3
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1, tests
after cooldown as the final electrical test in accordance with method 5004
of MIL-STD-883. The verified failures of group A, subgroup 1, after burn-in
divided by the total number of devices submitted for burn-in in that lot shall
be used to determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
TOTAL DOSE BIAS CIRCUIT
CF*
10k
5V
–
10k +
–5V
RH6200 F02
*CF IS COMPONENT OR PARASITIC
CAPACITANCE ENSURING STABILITY
TYPICAL PERFORMANCE CHARACTERISTICS
VOS Distribution, VCM = V+
80
VS = 5V, 0V
70
60
50
40
30
20
10
0
–1600–1200 –800 –400 0 400 800 1200 1600
INPUT OFFSET VOLTAGE (μV)
RH6200 G01
VOS Distribution, VCM = V–
80
VS = 5V, 0V
70
60
50
40
30
20
10
0
–1600–1200 –800 –400 0 400 800 1200 1600
INPUT OFFSET VOLTAGE (μV)
RH6200 G02
Supply Current vs Supply Voltage
30
TA = 125°C
25
20
TA = 25°C
15
TA = –55°C
10
5
0
02
4 6 8 10 12 14
TOTAL SUPPLY VOLTAGE (V)
RH6200 G03
4
rh6200mfa