English
Language : 

RH27C Datasheet, PDF (4/4 Pages) Linear Technology – Precision Operational Amplifier
RH27C
WU
TYPICAL PERFOR A CE CHARACTERISTICS
Input Offset Voltage
150
VS = ±15V
100 VCM = 0V
50
0
– 50
– 100
– 150
– 200
1
10
100
TOTAL DOSE KRAD (Si)
1000
RH27C • TPC03
Common Mode Rejection Ratio
170
VS = ±15V
160 VCM = ±11V
150
140
130
120
110
100
1
10
100
TOTAL DOSE KRAD (Si)
1000
RH27C • TPC06
Open-Loop Gain
170
VS = ±15V
160
RL = 2k
VOUT = ±10V
150
140
130
120
110
100
1
10
100
TOTAL DOSE KRAD (Si)
1000
RH27C • TPC04
Input Offset Current
75
VS = ±15V
VCM = 0V
50
25
0
– 25
– 50
1
10
100
TOTAL DOSE KRAD (Si)
1000
RH27C • TPC07
Input Bias Current
350
VS = ±15V
300 VCM = 0V
250
200
150
100
50
0
1
10
100
1000
TOTAL DOSE KRAD (Si)
RH27C • TPC05
Power Supply Rejection Ratio
140
VS = ±4V TO ±18V
130
120
110
100
90
80
70
1
10
100
TOTAL DOSE KRAD (Si)
1000
RH27C • TPC08
TABLE 2: ELECTRICAL TEST REQUIRE E TS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group B and D for Class S, and
Group C and D for Class B
End Point Electrical Parameters (Method 5005)
* PDA applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*,2,3,4,5,6,7
1,2,3,4,5,6,7
1
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1,
tests after cooldown as the final electrical test in accordance with method
5004 of MIL-STD-883 Class B. The verified failures of group A, subgroup
1, after burn-in divided by the total number of devices submitted for burn-
in in that lot shall be used to determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
4
Linear Technology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417q (408)432-1900
FAX: (408) 434-0507q TELEX: 499-3977 q www.linear-tech.com
I.D. No. 66-10-0155 Rev. C 0398
rh27cc LT/HP 0398 100 REV C • PRINTED IN USA