English
Language : 

LT1002_15 Datasheet, PDF (4/16 Pages) Linear Technology – Dual, Matched Precision Operational Amplifier
LT1002
WU
ATCHI G CHARACTERISTICS
The q denotes the specifications which apply over the temperature range – 55°C ≤ TA ≤ 125°C, VS = ±15V, unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
LT1002AM
MIN TYP MAX
LT1002M
MIN TYP MAX
UNITS
Input Offset Voltage Match
q
– 50 140
–
60 230
µV
Input Offset Voltage Tracking
IB+
Average Non-Inverting Bias
Current
IOS+
Non-Inverting Offset Current
IOS–
Inverting Offset Current
q
– 0.3 1.0
q
– ±1.5 ±6.0
q
– 1.5 6.5
q
– 1.5 6.5
–
0.4 1.5
– ±1.8 ±10.0
– 1.8 12.0
– 1.8 12.0
µV/°C
nA
nA
nA
∆CMRR Common Mode Rejection Ratio
Match
VCM = ±13V
q 106 126
102 124 –
dB
∆PSRR Power Supply Rejection Ratio
Match
VS = ±3V to ±18V
q 102 122
94 120 –
dB
The q denotes the specifications which apply over the temperature range 0°C ≤ TA ≤ 70°C, VS = ±15V, unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
LT1002AC
MIN TYP MAX
LT1002C
MIN TYP MAX
Input Offset Voltage Match
q
– 30 85
–
45 150
IB+
IOS+
IOS–
∆CMRR
∆PSRR
Input Offset Voltage Tracking
Average Non-Inverting Bias
Current
Non-Inverting Offset Current
Inverting Offset Current
Common Mode Rejection Ratio
Match
Power Supply Rejection Ratio
Match
VCM = ±13V
VS = ±3V to ±18V
q
– 0.3 1.0
q
– ±1.0 ±4.5
q
– 1.0 5.0
q
– 1.0 5.0
q
108 130 –
q
105 126 –
–
0.4 1.5
– ±1.2 ±7.0
– 1.2 8.5
– 1.2 8.5
105 128 –
98 124 –
UNITS
µV
µV/°C
nA
nA
nA
dB
dB
For MIL-STD components, please refer to LTC 883C data sheet for test
listing and parameters.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: Offset voltage measured with high speed test equipment,
approximately 1second after power is applied.
Note 3: This parameter is tested on a sample basis only.
Note 4: Long Term Input Offset Voltage Stability refers to the averaged
trend line of VOS versus Time over extended periods after the first 30 days
of operation. Excluding the initial hour of operation, changes in VOS during
the first 30 operating days are typically 2.5µV.
Note 5: Parameter is guaranteed by design.
Note 6: 10Hz noise voltage density is sample tested on every lot.
Devices 100% tested at 10Hz are available on request.
Note 7: The V + supply terminals are completely independent and may be
powered by separate supplies if desired (this approach, however, would
sacrifice the advantages of the power supply rejection ratio matching). The
V – supply terminals are both connected to the common substrate and
must be tied to the same voltage. Both V – pins should be used.
1002fb