English
Language : 

RH108A_15 Datasheet, PDF (3/4 Pages) Linear Technology – Operational Amplifier
RH108A
TABLE 2: ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group C and D End Point Electrical Parameters
(Method 5005)
*PDA applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*,2,3,4,5,6
1,2,3,4,5,6
1
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1,
tests after cooldown as the final electrical test in accordance with method
5004 of MIL-STD-883 Class B. The verified failures (including Delta
parameters) of group A, subgroup 1, after burn-in divided by the total
number of devices submitted for burn-in in that lot shall be used to
determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
TOTAL DOSE BIAS CIRCUIT
10k
15V 0.1μF
7
2–
1
30pF
86
8V 10k 3 +
4
–15V
0.1μF
RH108A TDBC
REVISION HISTORY (Revision history begins at Rev C)
REV DATE DESCRIPTION
C 11/10 Note 4 revised and added to Power Supply Rejection Ratio.
PAGE NUMBER
2
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representa-
tion that the interconnection of its circuits as described herein will not infringe on existing patent rights.
rh108afc
3