TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) TA = 25°C unless otherwise noted.
PARAMETER
CONDITIONS
10KRAD(Si)
20KRAD(Si)
50KRAD(Si) 100KRAD(Si) 200KRAD(Si)
MIN MAX MIN MAX MIN
MAX MIN MAX MIN MAX UNITS
Reference Voltage (Note 5)
IOUT = 10mA (VIN – VOUT) = 3V (K) 1.234 1.258 1.230 1.257 1.225 1.253 1.220 1.247 1.205 1.241
V
10mA ≤ IOUT ≤ IFULL LOAD
1.5V ≤ (VIN – VOUT) ≤ 15V
1.220 1.275 1.219 1.275 1.215 1.275 1.210 1.275 1.20 1.275 V
Line Regulation (Notes 1, 2)
IOUT = 10mA
1.5V ≤ (VIN – VOUT) ≤ 15V
0.2
0.21
0.23
0.25
0.3
%
Load Regulation (Notes 1, 2, 5) (VIN – VOUT) = 3V
10mA ≤ IOUT ≤ IFULL LOAD
0.3
0.3
0.3
0.3
0.3
%
Dropout Voltage (Note 3)
∆VREF = 1%, IOUT = 1.5A (K)
∆VREF = 1%, IOUT = 0.5A (H)
1.5
1.51
1.52
1.55
1.575 V
Current Limit
Minimum Load Current
Adjust Pin Current
(VIN – VOUT ) = 5V (K)
(VIN – VOUT ) = 25V (K)
(VIN – VOUT ) = 5V (H)
(VIN – VOUT ) = 25V (H)
(VIN – VOUT ) = 25V
1.5
0.05
0.5
0.020
1.5
0.049
0.5
0.019
10
120
1.5
0.048
0.5
0.019
10
120
1.5
1.5
A
0.047
0.045
A
0.5
0.5
A
0.018
0.017
A
10
10
10 mA
120
120
120 µA
Adjust Pin Current Change
(Note 5)
10mA ≤ IOUT ≤ IFULL LOAD
1.5V ≤ (VIN – VOUT) ≤ 15V
5
5
5
5
5
µA
Note 1: See thermal regulation specifications for changes in output voltage
due to heating effects. Line and load regulation are measured at a constant
junction temperature by low duty cycle pulse testing.
Note 2: Line and load regulation are guaranteed up to the maximum power
dissipation of 15W for RH1086MK and 3W for the RH1086MH. Power
dissipation is determined by the input/output differential voltage and the
output current. Guaranteed maximum power dissipation will not be
available over the full input/output voltage range.
Note 3: Dropout voltage is specified over the full output current range of
the device. Test points and limits are shown on the Dropout Voltage curve
in the LT®1086 data sheet.
Note 4: Guaranteed by design, characterization, or correlation to other
tested parameters.
Note 5: IFULL LOAD is defined in the Current Limit curves in the standard
data sheet. For compliance with 883 revision C current density
specifications, the RH1086MK is derated to 1A.
TABLE 2: ELECTRICAL TEST REQUIRE E TS
MIL-STD-883 TEST REQUIREMENTS
Final Electrical Test Requirements (Method 5004)
Group A Test Requirements (Method 5005)
Group C and D End Point Electrical Parameters
(Method 5005)
* PDA Applies to subgroup 1. See PDA Test Notes.
SUBGROUP
1*,2,3,4,5,6
1,2,3,4,5,6
1
PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1,
tests after cooldown as the final electrical test in accordance with method
5004 of MIL-STD-883 Class B. The verified failures of group A, subgroup
1, after burn-in divided by the total number of devices submitted for burn-
in in that lot shall be used to determine the percent for the lot.
Linear Technology Corporation reserves the right to test to tighter limits
than those given.
Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However,
no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the
interconnection of circuits as described herein will not infringe on existing patent rights.
3