English
Language : 

LTC1710_15 Datasheet, PDF (3/8 Pages) Linear Technology – SMBus Dual Monolithic High Side Switch
LTC1710
ELECTRICAL CHARACTERISTICS TA = 25°C, VCC = SW0D = 5V unless otherwise noted.
SYMBOL PARAMETER
tON
Output Turn-On Time
(100Ω/1µF Load)
tOFF
Output Turn-Off Time
(100Ω/1µF Load)
VIL
DATA/CLK Input Low Voltage
AD1 Input Low Voltage
VIH
DATA/CLK High Voltage
AD1 Input High Voltage
VOL
Data Output Low Voltage
CIN
Input Capacitance (DATA, CLK, AD1)
IIN
Input Leakage Current (DATA, CLK)
Input Leakage Current (AD1)
SMBus Related Specifications (Note 5)
fSMB
SMBus Operating Frequency
tBUF
Bus Free Time Between
Stop and Start
tSU:STA
tHD:STA
tSU:STO
tHD: DAT
tSU:DAT
tLOW
tHIGH
tf
tr
IPULL-UP
Start Condition Setup Time
Start Condition Hold Time
Stop Condition Setup Time
Data Hold Time
Data Setup Time
Clock Low Period
Clock High Period
Clock/Data Fall Time
Clock/Data Rise Time
Current Through External Pull-Up
Resistor on DATA Pin
CONDITIONS
VCC = 2.7V (From ON (Note 6) to VOUT = 90% VCC)
VCC = 5.5V (From ON (Note 6) to VOUT = 90% VCC)
VCC = 2.7V (From OFF (Note 7) to VOUT = 10% VCC)
VCC = 5.5V (From OFF (Note 7) to VOUT = 10% VCC)
VCC = 2.7V to 5.5V
q
VCC = 2.7V to 5.5V
q
VCC = 2.7V to 5.5V
q
VCC = 2.7V to 5.5V
q
VCC = 2.7V to 5.5V, IPULL-UP = 350µA
q
q
q
VCC = 2.7V to 5.5V
(Open-Drain Data Pull-Down Current Capacity)
MIN TYP
200
160
250
250
1.4
VCC – 0.2
0.18
5
10
4.7
4.7
4.0
4.0
300
250
4.7
4.0
100
MAX
0.6
0.2
0.4
±1
±250
100
50
300
1000
350
UNITS
µs
µs
µs
µs
V
V
V
V
V
pF
µA
nA
kHz
µs
µs
µs
µs
ns
ns
µs
µs
ns
ns
µA
The q denotes specifications which apply over the full operating
temperature range.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: Approximately 3% hysteresis is provided to ensure stable operation
and eliminate false triggering by minor VCC glitches.
Note 3: Measured from VCC > VUVLO to SMBus ready for DATA input.
Note 4: The oscillator frequency is not tested directly but is inferred from
turn-on time.
Note 5: SMBus timing specifications are guaranteed but not tested.
Note 6: ON is enabled upon receiving the Stop condition from the SMBus
master.
Note 7: OFF is enabled upon receiving the Stop condition from the SMBus
master.
3