English
Language : 

LTC2945 Datasheet, PDF (22/32 Pages) Linear Technology – Wide Range I2C Power Monitor Rail-to-Rail Input Range: 0V to 80V
LTC2945
APPLICATIONS INFORMATION
Table 3. CONTROL Register A (00h) - Read/Write
BIT NAME
OPERATION
A7 ADC Snapshot Mode Enable
Enables ADC Snapshot Mode; 1 = Snapshot Mode Enabled. Only channel selected by A6 and A5 is
measured by the ADC. After the conversion, the BUSY bit is reset and the ADC is halted.
0 = Snapshot Mode Disabled (Continuous Scan Mode. Default)
A6 ADC Channel Label for Snapshot Mode ADC Channel Label for Snapshot Mode
A6
A5 ADC Channel
A5
0
0 ΔSENSE (Default)
0
1 VIN
1
0 ADIN
A4 Test Mode Enable
A3 ADC Busy in Snapshot Mode
A2 VIN Monitor
A1 Shutdown Enable
A0 Multiplier Select
Test Mode Halts ADC Operation and Enables Writes to Internal ADC/LOGIC Registers;
1 = Enable Test Mode, 0 = Disable Test Mode (Default)
ADC Current Status; 1 = ADC Converting, 0 = ADC Conversion Completed (Default), Not Writable
Enables VDD or SENSE+ Voltage Monitoring; 1 = Monitor SENSE+ Voltage (Default),
0 = Monitor VDD Voltage
Enables Low-IQ / Shutdown Mode; 1 = Enable Shutdown, 0 = Normal Operation (Default)
1Se=leScetsleActDSINENoSr ES+E/NVDSDE+(/DVeDfDau(ldt)e,p0en=dSseolencAt 2A)DdINata for digital multiplication with SENSE data;
Table 4. ALERT Register B (01h) - Read/Write
BIT NAME
OPERATION
B7 Maximum POWER Alert
Enables Alert When POWER Calculation Data is > Maximum Power Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B6 Minimum POWER Alert
Enables Alert When POWER Calculation Data is < Minimum Power Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B5 Maximum ΔSENSE Alert
Enables Alert When ADC ΔSENSE Measurement Data is > Maximum ΔSENSE Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B4 Minimum ΔSENSE Alert
Enables Alert When ADC ΔSENSE Measurement Data is < Minimum ΔSENSE Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B3 Maximum VIN Alert
Enables Alert When ADC VIN Measurement Data is > Maximum VIN Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B2 Minimum VIN Alert
Enables Alert When ADC VIN Measurement Data is < Minimum VIN Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B1 Maximum ADIN Alert
Enables Alert When ADC ADIN Measurement Data is > Maximum ADIN Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
B0 Minimum ADIN Alert
Enables Alert When ADC ADIN Measurement Data is < Minimum ADIN Threshold;
1 = Enable Alert,
0 = Disable Alert (Default)
2945f
22