APPLICATIONS INFORMATION
Suspend Mode
The battery charger can also be disabled by pulling the
SUSP pin above 1.2V. In suspend mode, the battery
drain current is reduced to 1.5μA and the input current is
reduced to 8.5μA.
Charge Cycle Overview
When a battery charge cycle begins, the battery charger
first determines if the battery is deeply discharged. If the
battery voltage is below VTRKL, typically 2.9V, an automatic
trickle charge feature sets the battery charge current to
10% of the full-scale value.
Once the battery voltage is above 2.9V, the battery charger
begins charging in constant-current mode. When the
battery voltage approaches the 4.2V (LTC3559) or 4.1V
(LTC3559-1) required to maintain a full charge, otherwise
known as the float voltage, the charge current begins to
decrease as the battery charger switches into constant-
voltage mode.
Trickle Charge and Defective Battery Detection
Any time the battery voltage is below VTRKL, the charger
goes into trickle charge mode and reduces the charge
current to 10% of the full-scale current. If the battery
voltage remains below VTRKL for more than 1/2 hour, the
charger latches the bad-battery state, automatically termi-
nates, and indicates via the CHRG pin that the battery was
unresponsive. If for any reason the battery voltage rises
above VTRKL, the charger will resume charging. Since the
charger has latched the bad-battery state, if the battery
voltage then falls below VTRKL again but without rising past
VRECHRG first, the charger will immediately assume that
the battery is defective. To reset the charger (i.e., when
the dead battery is replaced with a new battery), simply
remove the input voltage and reapply it or put the part in
and out of suspend mode.
Charge Termination
The battery charger has a built-in safety timer that sets the
total charge time for 4 hours. Once the battery voltage rises
above VRECHRG and the charger enters constant-voltage
mode, the 4-hour timer is started. After the safety timer
expires, charging of the battery will discontinue and no
more current will be delivered.
Automatic Recharge
After the battery charger terminates, it will remain off,
drawing only microamperes of current from the battery.
If the portable product remains in this state long enough,
the battery will eventually self discharge. To ensure that the
battery is always topped off, a charge cycle will automati-
cally begin when the battery voltage falls below VRECHRG. In
the event that the safety timer is running when the battery
voltage falls below VRECHRG, it will reset back to zero. To
prevent brief excursions below VRECHRG from resetting the
safety timer, the battery voltage must be below VRECHRG
for more than 1.7ms. The charge cycle and safety timer
will also restart if the VCC UVLO or DUVLO cycles low and
then high (e.g., VCC is removed and then replaced) or the
charger enters and then exits suspend mode.
Programming Charge Current
The PROG pin serves both as a charge current program
pin, and as a charge current monitor pin. By design, the
PROG pin current is 1/800th of the battery charge current.
Therefore, connecting a resistor from PROG to ground
programs the charge current while measuring the PROG pin
voltage allows the user to calculate the charge current.
Full-scale charge current is defined as 100% of the con-
stant-current mode charge current programmed by the
PROG resistor. In constant-current mode, the PROG pin
servos to 1V if HPWR is high, which corresponds to charg-
ing at the full-scale charge current, or 200mV if HPWR
is low, which corresponds to charging at 20% of the full-
scale charge current. Thus, the full-scale charge current
and desired program resistor for a given full-scale charge
current are calculated using the following equations:
ICHG
=
800V
RPROG
RPROG
=
800V
ICHG
3559fb
12