Features
n RS485/RS422 Transceiver: 2500VRMS for 1 Minute
n UL Recognized File #E151738
®
n Isolated DC Power: 5V at Up to 200mA
n No External Components Required
n 20Mbps or Low EMI 250kbps Data Rate
n High ESD: ±15kV HBM on Transceiver Interface
n High Common Mode Transient Immunity: 30kV/μs
n Integrated Selectable 120Ω Termination
n 3.3V (LTM2881-3) or 5.0V (LTM2881-5) Operation
n 1.62V to 5.5V Logic Supply Pin for Flexible Digital Interface
n Maximum Continuous Working Voltage: 560VPEAK
n High Input Impedance Failsafe RS485 Receiver
n Current Limited Drivers and Thermal Shutdown
n Compatible with TIA/EIA-485-A and PROFIBUS
n High Impedance Output During Internal Fault Condition
n Low Current Shutdown Mode (< 10µA)
n General Purpose CMOS Isolated Channel
n Small, Low Profile (15mm × 11.25mm)
Surface Mount BGA and LGA Packages
Applications
n Isolated RS485/RS422 Interface
n Industrial Networks
n Breaking RS485 Ground Loops
n Isolated PROFIBUS-DP Networks
LTM2881
Complete Isolated
RS485/RS422 µModule
Transceiver + Power
Description
The LTM®2881 is a complete galvanically isolated full-du-
plex RS485/RS422 µModule® (micromodule) transceiver.
No external components are required. A single supply
powers both sides of the interface through an integrated,
isolated, low noise, efficient 5V output DC/DC converter.
Coupled inductors and an isolation power transformer
provide 2500VRMS of isolation between the line transceiver
and the logic interface. This device is ideal for systems
where the ground loop is broken allowing for large com-
mon mode voltage variation. Uninterrupted communica-
tion is guaranteed for common mode transients greater
than 30kV/μs.
Maximum data rates are 20Mbps or 250kbps in slew
limited mode. Transmit data, DI and receive data, RO, are
implemented with event driven low jitter processing. The
receiver has a one-eighth unit load supporting up to 256
nodes per bus. A logic supply pin allows easy interfacing
with different logic levels from 1.62V to 5.5V, independent
of the main supply.
Enhanced ESD protection allows this part to withstand up
to ±15kV (human body model) on the transceiver interface
pins to isolated supplies and ±10kV through the isolation
barrier to logic supplies without latch-up or damage.
L, LT, LTC, LTM, Linear Technology, the Linear logo and µModule are registered trademarks of
Linear Technology Corporation. All other trademarks are the property of their respective owners.
Typical Application
Isolated Half-Duplex RS485 μModule Transceiver
LTM2881 Operating Through 35kV/μs CM Transients
3.3V (LTM2881-3)
5V (LTM2881-5)
VCC
VL
RO
RE
TE
DE
DI
PWR
LTM2881
VCC2
5V
A
B
Y
Z
AVAILABLE CURRENT:
150mA (LTM2881-5)
100mA (LTM2881-3)
MULTIPLE SWEEPS
OF COMMON MODE
TRANSIENTS
500V/DIV
TWISTED-PAIR
CABLE
1V/DIV
1V/DIV
DI
RO
50ns/DIV
2881 TA01a
GND
GND2
2881 TA01
2881fh
For more information www.linear.com/LTM2881
1