English
Language : 

LTC3554 Datasheet, PDF (5/36 Pages) Linear Technology – Micropower USB Power Manager with Li-Ion Charger and Two Step-Down Regulators
LTC3554
PUSHBUTTON INTERFACE ELECTRICAL CHARACTERISTICS
The l denotes specifications that apply over the full operating temperature range, otherwise specifications are at TA = 25°C.
VBAT = 3.8V unless otherwise noted.
SYMBOL PARAMETER
Pushbutton Pin (ON)
CONDITIONS
MIN TYP MAX UNITS
VCC_PB
VON_TH
ION
Pushbutton Operating Supply Range
ON Threshold Rising
ON Threshold Falling
ON Input Current
(Notes 4 , 9)
VON = VCC (Note 4)
l 2.7
5.5
V
0.8
1.2
V
0.4
0.7
V
–1
1
μA
RPB_PU
Pushbutton Pull-Up Resistance
Logic Input Pins (PWR_ON1, PWR_ON2)
Pull-Up to VCC (Note 4)
200 400
600
kΩ
VPWR_ONx
PWR_ONx Threshold Rising
PWR_ONx Threshold Falling
0.8
1.2
V
0.4
0.7
V
IPWR_ONx
PWR_ONx Input Current
Status Output Pins (PBSTAT, PGOOD)
–1
1
μA
IPBSTAT
PBSTAT Output High Leakage Current VPBSTAT = 3V
–1
1
μA
VPBSTAT
PBSTAT Output Low Voltage
IPBSTAT = 3mA
0.1
0.4
V
IPGOOD
PGOOD Output High Leakage Current VPGOOD = 3V
–1
1
μA
VPGOOD
PGOOD Output Low Voltage
IPGOOD = 3mA
0.1
0.4
V
VTHPGOOD PGOOD Threshold Voltage
(Note 10)
–8
%
Pushbutton Timing Parameters (Note 11)
tON_PBSTATL Minimum ON Low Time to Cause PBSTAT ON Brought Low During Power-On (PON) or
50
ms
Low
Power-Up (PUP1, PUP2) States
tON_PBSTATH Delay from ON High to PBSTAT High
Power-On (PON) State, After PBSTAT Has
Been Low for at Least tPBSTAT_PW
900
μs
tON_PUP
Minimum ON Low Time to Enter
Starting in the Hard Reset (HR) or Power-Off
400
ms
Power-Up (PUP1 or PUP2) State
(POFF) States
tON_HR
Minimum ON Low Time to Hard Reset ON Brought Low During the Power-On (PON)
4
5
6
s
or Power-Up (PUP1, PUP2) States
tPBSTAT_PW PBSTAT Minimum Pulse Width
Power-On (PON) or Power-Up (PUP1, PUP2)
40
50
ms
States
tEXTPWR
Power-Up from USB Present to Power-Up Starting in the Hard Reset (HR) or Power-Off
100
ms
(PUP1 or PUP2) State
(POFF) States
tPON_UP
Any PWR_ONx High to Power-On State Starting With Both PWR_ONx Low in the
Power-Off (POFF) State
900
μs
tPON_DIS
tPUP
tPDN
PWR_ONx Low to Buckx Disabled
Power-Up (PUP1 or PUP2) State Duration
Power-Down (PDN1 or PDN2) State
Duration
1
μs
5
s
1
s
tPGOODH
Bucks in Regulation to PGOOD High
All Enabled Bucks Within PGOOD Threshold
230
ms
Voltage
tPGOODL
Bucks Disabled to PGOOD Low
All Bucks Disabled
100
μs
Note 1. Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2. The LTC3554 is guaranteed to meet performance specifications
from 0°C to 85°C. Specifications over the –40°C to 85°C operating
temperature range are assured by design, characterization and
correlation with statistical process controls.
3554p
5