English
Language : 

AXH010A0X3 Datasheet, PDF (9/17 Pages) Lineage Power Corporation – 3.0Vdc - 5.5Vdc input; 0.75 to 3.63Vdc Output; 10A Output Current
Data Sheet
April 1, 2008
Austin LynxTM SIP Non-isolated Power Modules, Programmable:
3.0Vdc – 5.5Vdc input; 0.75 to 3.63Vdc Output; 10A Output Current
Characteristic Curves (continued)
The following figures provide thermal derating curves for the Austin LynxTM SIP modules.
12
10
8
6
4
NC
2
100 LFM
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE, TA OC
Figure 19. Derating Output Current versus Local
Ambient Temperature and Airflow (Vin = 5.0Vdc,
Vo=0.75Vdc).
12
10
8
6
4
NC
2
100 LFM
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE, TA OC
Figure 20. Derating Output Current versus Local
Ambient Temperature and Airflow (Vin = 5.0Vdc,
Vo=1.8 Vdc).
12
10
8
6
4
NC
2
100 LFM
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE, TA OC
Figure 21. Derating Output Current versus Local
Ambient Temperature and Airflow (Vin = 5.0Vdc,
Vo=2.5 Vdc).
12
10
8
6
4
NC
2
100 LFM
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE, TA OC
Figure 22. Derating Output Current versus Local
Ambient Temperature and Airflow (Vin = 5.0Vdc,
Vo=3.3 Vdc).
12
10
8
6
4
NC
2
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE, TA OC
Figure 23. Derating Output Current versus Local
Ambient Temperature and Airflow (Vin = 3.3Vdc,
Vo=2.5 Vdc).
LINEAGE POWER
9